Humidity Level & Timer 2 digit display
The indicator features 3 functions:
1. when you set the humidity, it will indicate the humidity that you have selected
2. when you program the time for the unit to turn on and off, it will show the hours.
3. When the environment humidity is lower than 35%, it will show "LO"
4. When the environment humidity is higher than 95%, it will show "HI"
Functions
A. On/Off button
B. Press arrow down to set lower the humidity
C.Press arrow up to set higher humidity
D. Timer button
OPERATING INSTRUCTIONS
1. Plug in the unit.
2. Press
button to start operation, the power indicator will be on. Press it again to stop operation.
3. Press
or
5% intervals or "CO".
After a period of working,when environment humidity is lower than the selected humidity by 2%, compressor will stop ;
When environment humidity is equal to or higher than the selected humidity by 3%, compressor will restart once
3-minute compressor protection time over.
When setting the humidity to " CO ", the compressor will run continuously .
4.press
button can be timer setting:
Press the button to program the time when the unit turns on and turns off. If you want to cancel the timer program-
ming, press the button to adjust the time at 00, and press the button ,it will be circulate from 00-01-02......23-24.It
is the programmed time to switch the machine. The programmed time will be cancelled when to switch compressor
manually each time. The programmed time remains unchanged if the machine stops to wok due to water full or during
defrosting
Noted: when ambient humidity reaches what you set before, both compressor and fan motor stop for 60mins firstly,
and then, fan motor works for 3mins to detect ambient humidity, if it is higher than set, both compressor and motor
works again; If it is lower than set, both compressor and motor stop for 60mins, and then motor works for 3mins again;
button to set the desired humidity level in the room, which can be set from 30% to 90% at