INSTALLATION – CONTROL BEFORE CONNECTION
Before connection, please consult the following element:
BATTERY
Unisolar has an automatic voltage detection. For its correct functioning, please check:
- If the battery voltage is higher than 6V (required voltage for the startup of the solar charge controller)
- For 24V batteries, that the voltage is not lower than 18V.
For flooded batteries, check the electrolyte level. If necessary, complete before charging.
For coupling, proceed as follows:
IN SERIES
Tips :
In
case
of
parallel
connection,
favour
diagonal wiring for a
standardization of the
charge/discharge
Prefer a high-capacity
battery
to
2
connected in parallel, for
equal capacity
PHOTOVOLTAIC PANEL
Check that the photovoltaic panel power or the panel photovoltaic park does not exceed 60V
ELECTRICAL DEVICES – 12/24V CONTROLLED OUTPUT
Before connecting your devices to the solar charge controller and to prevent the solar charge controller
from switching into overload protection, check that the devices do not exceed the Unimppt's power rating
(Refer to the 12V/24V controlled output passage for more details).
26/59
IN PARALLEL
small
Do
not
batteries
different
different
different technologies
www.uniteck.fr
IN SERIES AND IN PARALLEL
couple
with
capacities,
age
or