The normal status of the function is 0°C by default
•
EN
to change this value, the convector must be in
"Off" mode, when you press the
buttons for three seconds the display will show a
blinking "0oc". You can press either the
button to reach the „-4oc" to „4oc" range, then you
need to wait for 3 seconds and the function will be
automatically stored.
•
to check what correction has been set, the
convector must be in "Off" mode, when you press
the
and "On/Off" buttons for three seconds you
will see the set temperature blinking on the display.
By pressing the
value within a range from „-4oc" to „4oc".
Note: After activating the Return to Factory Settings
function a new temperature correction has to be
entered, the value by default is 0°С)
Adaptive start
•
Adaptive start control is a function which predicts and
initiates the optimal start of heating up in order to
reach the set temperature in the desired time.
•
this function is enabled by default
•
to change the value, the convector must be in "Off"
mode, when you press the „
for three seconds the display will show a blinking "A_
On". You need to press the „
then you need to wait for 3 seconds and the function
will be automatically stored.
•
To return to „ON" status – the convector must be
in "Off" mode; when you press the
buttons for three seconds the display will show a
blinking "AOFF"; you need to press the
reach „A_On", then you need to wait for 3 seconds
and the function will be automatically stored.
This function can be set according to your needs.
The appliance operates for 17 hours following the set
"comfort" temperature until it reaches a stable status – this
is the reference comfort temperature. Also, a temperature
lower than the comfort one, with a difference from 4°C ±
1°С, has to be set for a period of minimum 7 hours. When
the adaptive operation is enabled, leave the electronic
thermoregulator of the appliance to operate for 4 cycles
(4 х 24 hours) of comfort cycles (17 hours) and lowered
temperature (7 hours). Upon completion of the last period
of low temperature, the comfort temperature should be
reached within ± 30 minutes deviation from the set time,
with a maximum difference of ± 1°C from the reference
comfort temperature.
"Protection from children"
You can lock the buttons by continuously pressing
the arrows
and "Timer" buttons simultaneously, in
order to prevent any changes to the settings. When this
function is enabled you will see a lit green LED above
the "padlock" icon. Repeat the same action to unlock
the buttons.
6
Operation and Storage Manual
and "On/Off"
or
or
buttons you can set a new
" and "Timer" buttons
" button to reach „AOFF";
and "Timer"
button to
Note: If you press any of the buttons when the keypad is
locked, the display will show „LOC_"
"Open window"
The appliance is equipped with an integrated electronic
device which automatically switches off the heating
power if a sharp decrease of temperature is found in
the room, when a window or a door is open. When the
temperature in the room begins increasing the heating
will be automatically restored. To activate this function
you need to press the "Window" button; a blinking
green LED indicates that the function is enabled.
Permanently lit green LED indicates that the appliance is
not heating up. To disable the "Open window" function
you need to press the "Window" button.
Note: When the "Open window" function is enabled, the
"Anti-frost" function does not work!
Settings in „Weekly programmer 24/7"
Entering settings mode of "Weekly programmer"
is possible only after the time and the day of the
week have already been set in the appliance..
To enter and exit the settings mode you need to
continuously press the "Timer" button.
There are three parameters to be set – day of the
week, time and temperature; switching among the
three parameters is done by shortly pressing the
"Timer" button in the following sequence: day, time,
temperature. To store the settings, press shortly the
"Timer" button after you finish the temperature setting.
You can change the value of each parameter by using
the
and
buttons.
Conditions for settings storing
After a point has been stored, it cannot be changed
a.
any more until you exit the current setting.
Upon storing the first set point of a specific day in the
b.
current setting, all previously set points of the day are
cleared.
Storing further points of a specific day is possible only
c.
for the hours remaining until the end of the day, after
the last stored point.
When you have stored a point in the last hour of the
d.
day – 23.5h, you cannot store any more points for this
day in the current setting, and the display will show
"FUL" and the number of the day.
If nothing is stored in the current setting for a specific
e.
day, it will keep the existing stored points up to the
current setting.
The purpose of the settings is to store the three
parameters in the so called "SET POINTS", where the
temperature set for each set point is implemented until
the next one is reached.
Example: If you have stored the temperature to be 22°C at 7
h and you wish the temperature to remain the same until 19
h (you plan the temperature to increase to 23°C then), you do