Safety Instructions; Mains Connection - Milwaukee MXFC Manual Original

Ocultar thumbs Ver también para MXFC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
TECHNICAL DATA
Voltage range ...................................................................................
Quick charge current ........................................................................
Weight according EPTA-Procedure 01/2014 ....................................
Recommended ambient charging temperature ................................
WARNING Read all safety warnings, instructions,
illustrations and specifi cations provided with this power tool.
Failure to follow all instructions listed below may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS

Do not dispose of used battery packs in the household refuse or by
burning them. Milwaukee Distributors off er to retrieve old batteries
to protect our environment.
Only the following battery packs can
be charged with this charger:
Battery
Cell
Cat. No.
Type
MXFCP203 Li-Ion
MXFXC406 Li-Ion
Do not try to charge non-rechargeable
batteries with this charger.
Do not store the battery pack together with metal objects (short
circuit risk).
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Never break open battery packs or chargers and store only in dry
rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains supply. Do
not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new one.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
Use only System MXF chargers for charging System MXF battery
packs. Do not use battery packs from other systems.
This appliance is not intended to be
used or cleaned by persons with
reduced physical, sensory or mental
capabilities, or lack of experience or
knowledge, unless they have been
given instructions concerning the safe
use of the appliance by a person
legally responsible for their safety.
They should be supervised whilst
using the appliance. Children shall not
use, clean or play with this appliance,
which when not in use should be
secured out of their reach.
Warning! To reduce the risk of fi re, personal injury, and product
damage due to a short circuit, never immerse your tool, battery
pack or charger in fl uid or allow a fl uid to fl ow inside them.
Corrosive or conductive fl uids, such as seawater, certain industrial
8
ENGLISH
470 355 - MXFC.indd 8
470 355 - MXFC.indd 8
BATTERY CHARGER
DC
Capacity
Cell
Volts
No.
72 V ≤ 3.0 Ah
20
72 V ≤ 6.0 Ah
2 x 20
MXFC
..........................72 V
.........................4,5 A
.......................2,73 kg
..................... +5...+40 °C
chemicals, and bleach or bleach containing products, etc., can
cause a short circuit.
SPECIFIED CONDITIONS OF USE
This charger charges MXFCP203 and MXFXC406 Milwaukee
Li-Ion battery packs.
Do not use this product in any other way as stated for normal use.

MAINS CONNECTION

Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect
to sockets without an earthing contact as the design conforms to
safety class II.
CHARGING TIME
Battery Cat. No.
Volts
MXFCP203
72 V
MXFXC406
72 V
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED on the
battery indicates the state of charge.
If it is not used for long periods, the rechargeable battery will
switch to the non-operative state.
When fully discharged the rechargeable battery switches off
automatically (depth discharge not possible).
Under extreme circumstances, the internal temperature of the
battery could become to high. If this happens, the battery will shut
down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on the
rechargeable battery. The battery can be left in the electric tool
while the reading is taken but it must be switched off at least one
minute beforehand (otherwise the display will be inaccurate). The
number of LEDs illuminated indicates the state of charge. A
fl ashing LED indicates a max. power reserve of 10%.
As a general principle, if the electric tool should fail to work after
inserting the rechargeable battery, then the battery should be
plugged into the charger. The displays on the battery and charger
will then provide information about the condition of the battery.
In low temperatures work may continue at reduced output.
CHARACTERISTICS
After inserting the battery into the reception of the charger the
battery will automatically be charged (red control lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once the
battery reaches the correct charging temperature (0°C...40°C). The
max. charging current is fl owing when the temperature of the
Li-Ion-battery is between 0°C and 30°C.
The battery's charging time is between 45 min and 90 min,
depending on the state of discharge.
Once the battery is fully charged, the LED on the charger changes
from red to green.
Remove the battery pack from the tool for charging when
convenient for you and your job. Milwaukee batteries do not
develop a memory when charged after only a partial discharge. It
is not necessary to run down the battery pack before placing it on
the charger.
Capacity
Charging Time
approx.
≤ 3.0 Ah
55 min
≤ 6.0 Ah
90 min
27.05.2020 10:04:49
27.05.2020 10:04:49

Publicidad

Tabla de contenido
loading

Tabla de contenido