Electrical Connections

Process D: Steps 1 through 4, At The House, continued
STEP
4A
2-wire pump (with a ground wire) or 3-wire pump (with a ground wire)
2-WIRE
(no control box required): Remove pressure switch cover.
Connect two pump wires to the two inside pressure switch
terminals (numbers 2 & 3). Run wires from two outside
pressure switch terminals (numbers 1 & 4) to fuse box/power
supply. Connect green ground wire to the two ground screws on
base of pressure switch.

2-WIRE CONNECTIONS

1
2
FROM
PUMP
FUSE AND CIRCUIT BREAKER SIZE GUIDE
NAME
PUMP
HORSE
PLATE
WIRING
POWER
VOLTS
1/2
115
1/2
230
TWO
3/4
230
WIRE
1
230
1-1/2
230
1/2
230
3/4
230
THREE
WIRE
1
230
1-1/2
230
4 INCH MOTOR
MINIMUM SERVICE REQUIREMENTS
HP
Volts
1/3
115
1/3
115
1/3
230
1/3
230
1/2
115
1/2
115
1/2
230
1/2
230
3/4
230
3/4
230
1
230
1
230
1-1/2
230
1-1/2
230
23833A09
Warning! Failure to follow these instructions and comply with all codes may cause serious
bodily injury and/or property damage. Before installing or servicing your pump, be certain
the pump power source is turned off and disconnected.
4
3
TO FUSE BOX
& POWER
SUPPLY
APPROX.
LOCKED
CIRCUIT
MAX.
ROTOR
& STD.
FUSETRON
AMPS
AMPS
FUSE
CARTRIDGE
11.9
62.4
30
5.9
31.2
15
8.0
40.2
20
9.6
46.0
25
13.1
56.8
35
5.9
23.1
15
8.0
33.1
20
9.6
42.0
25
11.6
52.8
30
Minimum
Wire
Service
2W
200 amp
3W
200 amp
2W
60 amp
3W
60 amp
2W
200 amp
3W
200 amp
2W
60 amp
3W
60 amp
2W
100 amp
3W
100 amp
2W
100 amp
3W
100 amp
2W
200 amp
3W
200 amp
3-WIRE
Connect red, black, and yellow pump wires to control box
terminals labelled "R", "B", and "Y" respectively. Connect
green ground wire to one of the screws labelled "GND".
Remove pressure switch cover. Run a wire from other "GND"
screw to one of the ground screws at base of pressure switch.
Run wires from control box terminals labelled "L1" and "L2"
to two inside pressure switch terminals (numbers 2 & 3).
Run wires from two outside pressure switch terminals (lines 1
& 4) to fuse box/power supply. Run wire from ground screw to
fuse box ground bar.
*For Minimum Entrance Box Service Rating see chart below.
3-WIRE CONNECTIONS
CONTROL BOXES NEEDED
TIME
RF303 for 1/2 hp pumps
RELAY &
RF304 for 3/4 hp pumps
RF305 for 1 hp pumps
RF306 for 1-1/2 hp pumps
15
R3071B for 2 hp pumps
7
9
12
15
7
9
12
15
FROM
CONTROL
BOX
0
TO PRESSURE
SWITCH
2
1
3
4
TO FUSE BOX
& POWER
SUPPLY
Bag #23834A004
FROM
PUMP