Munich LED
1x
70
600mm
668mm (6 clips)
1200mm
1278mm (8 clips)
1500mm
1578mm (10 clips)
230V ac
WARNING
INSTALLATION MUST BE CARRIED OUT BY QUALIFIED
PERSONNEL.
IMPROPER HANDLING OF THESE COMPONENTS
MAY DAMAGE THE PROPER FUNCTIONING OF THIS
PRODUCT AND WILL VOID THE MANUFACTURER'S
WARRANTY.
THE WARRANTY COVERS ONLY AND EXCLUSIVELY
THE PRODUCT SUPPLIED.
FAILURES CAUSED BY INSTALLATIONS OTHER THAN
THOSE INDICATED IN THE REBT 2002 EXEMPT FROM
THE WARRANTY PERIOD FOR DAMAGED PRODUCTS.
THE APPLICATION OF ARTICLE 16, POINT 3 OF THE
REBT. IS OBLIGATORY FOR INDOOR INSTALLATIONS.
1/3
noviembre 2019
2x
110
417
1027
1327
[GRÁFICOS: Unidades en mm/ GRAPHICS: Units in mm/GRAPHIQUES: Unités en mm/GRÁFICOS: Unidades em mm]
PROPERTIES:
• Waterproof IP65 screen.
• Polycarbonate body and diffuser.
PRECAUTIONS:
• Disconnect power before handling the product and restore power after
handling or installation is complete.
• This product must be installed by qualified personnel. If in doubt, consult a
specialized technician.
• Keep him away from children.
• Do not handle the product with wet hands.
• For storage, store the product in a dry place protected from shock and
moisture.
• This product is for outdoor use, IP65, do not puncture it and in case the
product shows symptoms of being broken replace it with a new one.
• If the polycarbonate product or diffuser is damaged, replace it immediately
with a new one.

SURFACE MOUNTING:

1. Turn off the power..
2. Drill the surface on which the luminaire is to be installed, always respecting
the distance between the anchors of each screen (see graphics).
3. Attach the anchors included in the luminaire to the surface.
4. Attach the screen body to the previously placed anchors.
5. Pass the supply line through the cable gland, making sure it is securely
fastened.
6. Connect the cables to the connection terminal block, taking into account
that the green-yellow cable is the grounding cable and is marked with the
symbol:
7. Attach the diffuser using the clips provided.
8. Restore power.
For suspended installation of the luminaire, follow the steps described above
but fasten the screws installed on the ceiling to the luminaire by means of a
steel chain or cable to ensure that the luminaire is correctly fixed and cannot
fall out.

LAMP REPLACEMENT:

1. Turn off the power
2. Remove the diffuser from the luminaire using the fixing clips.
3. Turn the tube 90° and pull it out.
4. Insert the ends of the new tube into the holes of the lamp holder
and rotate it so that it is fixed respecting the polarity of the LED tube.
5. Close the luminaire again.
6. Restore power