Classification
IEC/EN 60529 IP66,
ISO 4892-2 method A, cycle 1 (3000 hrs),
Type 4X of NEMA 250,
Vibration: Class 4M3 IEC 60721-3-4,
Shock: Class 4M4 IEC 60721-3-4,
Delimitations: 4M4 IEC TR 60721-4-4
The start–up time is 2 minutes at 0 °C to 50 °C (32 °F to 122 °F).

Power consumption

Product
AXIS T99A 100–240 V AC
AXIS T99A 24 V AC/DC*
Important
*When using the 22 m (72 ft) AXIS Cable 24 V DC/24–240 V AC, a power supply capable of
delivering 400 W is required to compensate for the power loss in the cable.
NO TICE
TICE
NO
NO
TICE
The typical power consumption values are based on the following:
• Any losses in the power cable disregarded
• No pan/tilt/zoom/focus/wiper motors active
• Temperature at 25 °C (all heaters off)
• One H.264 stream at maximum resolution
• MJPEG stream recorded to SD card
AXIS T99A Positioning Unit
Temperature
Operation:
-50 °C to 60 °C
(-58 °F to 140 °F)
Cold start:
-40 °C to 60 °C
(-40 °F to 140 °F)
Typical consumption
10 W
37
Humidity
10–100% RH
(non-condensing)
Max consumption
169 W