Jet Massage
It is important to read this manual carefully to ensure the functionality and service life of the pool equipment.
Pahlén AB is not responsible for product warranty or damage resulting from improper installation, incorrect operation or poor
maintenance.
Product description
A massage station in the pool provides a very comfortable massage jet of water mixed with air that, for example, soothes the
back and neck.
The complete massage station consists of a dedicated circulation pump, a control box, 1-6 massage jet nozzles, a start button,
at least 2 outlets, as well as the required number of connections and pipes. The number of massage nozzles dictates the size
of the pump and the number of outlets. The nozzles are available in two versions: gentle or medium massage.
Technical data
Pump
0.55kW, 1.1kW, 2.2kW or 4.0kW
Voltage
1N~230V, 3~400V, 3~230V
Current strength
1,5–8A
IP class
Pump IP55, Control box IP45
General information
Recommended values for water quality:
Total chlorine content: max 3.5 mg/liter (ppm)*
Chloride (salt) content: max 250 mg/liter
pH-value:
7.2–7.6
Alkalinity:
60–120 mg/liter (ppm)
Calcium hardness:
100–300 mg/liter (ppm)
Iron:
max 0.1 mg/l *
Copper:
max 0.2 mg/l *
Manganese:
max 0.05 mg/l *
Phosphorus:
max 0.01 mg/l *
Nitrate:
max 50 mg/l *
Outside these values the product warranty does not apply.
Winter closure
1. Undo the front and the massage nozzle/button.
2. Block up the hole with a winter plug (not included). Use a plug with a conical expander or R1½" thread.
Installation, general
The example in this instruction features two nozzles.
• The massage nozzles must be placed 100-600 mm below the water level of the
pool. The massage nozzle air hose must run out ABOVE the water surface.
• The start button may be sited either above or below the surface of the water, in the
pool wall, or in another location (air hose = max 3 m).
• The outlets must be sited 2 metres apart.
• T-pipes, angles and PVC pipes are not included.
Control box (and its start button), pump and outlets
must be fitted/installed in accordance with the
instructions that come with each product*.
* P ump: Pahlén instruction MA25-01.
* Outlet: Pahlén instruction MA55-29.
* Automation cabinet/Start button: Pahlén instruction MA25-07.
These instructions are also available for download from the Pahlén website.
9
ENGLISH
* Complies to EN 16713-3
REV
1
Bild 1.
DESCRIPTI