Descargar Imprimir esta página

Technical Specifications - Riello Elettronica CARDIN S46 Serie Guia De Inicio Rapido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CARDIN ELETTRONICA spa
Via del lavoro, 73 – Z.I. Cimavilla 31013 Codognè (TV) Italy
Tel:
Fax:
email (Italy):
email (Europe):
Http:
QUARTZ DIGITAL RADIO CONTROL WITH PROGRAMMABLE CODE 230V
Description
The S46 Radio control system consists of one or more transmitters and one or more
receivers which can be combined to meet the specific needs of the client.
The receiver model offers the following possibilities: up to 4 channels and a number
of possible combinations equal to 19683, (these are programmable through the use
of a block of 9 three-way dip-switches).
Use
The S46 radio control allows the remote activation of electrical and electronic appliances
with its best use in the following areas: automatic opening systems and in all systems
which require remote control activation (without wires) using secret codes.
Compatibility
• The transmitters are fitted with a jumper "JC" (see drawings 3-4) to maintain
compatibility with receivers of the series non "C".
- Jumper inserted:
Compatible with NON series "C" receivers
- Jumper not inserted:
Compatible with series "C" receivers
• The receiver RVQ046100 is a non "C" type receiver therefore you should
make sure that the jumper on the transmitter is inserted in position "B"
Transmitter versions
TRQ466200
Pocket size transmitters
TRQ466400
Pocket size transmitters
Receiver versions
RVQ046100
Outdoor receivers (CS1304A/B)
4-channel outdoor receivers IP55 (fig. 5)
The receiver is in an outdoor case fitted with a 12-way terminal board (printed circuit
CS1304A/B) with the following electrical connections:
230 Vac between binding posts 1-2.
Interchangeable channel modules
In the receivers with container the interchangeable channel modules can only have the
following configurations and must not be mixed:
- from 1 to 4 impulsive relay strips MCC4491R0 1 channel
- one ON-OFF relay strip MCC0381M0
- one timer relay strip MCC0381T0
Receiver installation
Depending on the type of installation, work out the position in which the programmer
will be situated remembering that the site must be:
- a position safe from accidental collision;
- high enough above the ground to be safe from pools of water;
- in a position which the technician can easily reach.
The fixing of the case type receiver is carried out by using "fast-fitting" brackets.
The bracket should be fixed to the wall using two raw plugs (check that it is plumb
to the wall), the case can then be slid onto the bracket and fastened securely to
the wall.
The slot-in circuit located towards the bottom of the case can be easily extracted
to facilitate wiring up the device. If any repair work is necessary the case can be
easily extracted by pushing upwards the action of which will separate it from the
bracket.
Electrical connection (fig. 5)
Before connecting the device to the mains make sure that:
- the voltage and frequency rated on the data plate conform to those of the mains
supply;
- a bipolar circuit breaker which leaves at least 3 mm between the contacts has
been installed between the device and the mains;
- the high voltage 230V wires pass through the holes marked "A" and are routed
separately from the low voltage wires which pass through the holes marked "B"
and "C";
RECEPTION FREQUENCY
ATTENTION
The transmission frequency of these products varies
according to the approved frequency and eventual
personalisation in the country of destination.
Country
Frequency
Only Italy
29,875 MHz
Europe
27,195 MHz
USA
27,195 MHz
+39/0438.404011
+39/0438.401831
Sales.office.it@cardin.it
Sales.office@cardin.it
www.cardin.it
2 channels
4 channels
4 channels
1 channel ON-OFF
1 channel 0,5 to 120 seconds.
RECEIVER
- local oscillation frequency tolerance ....................30p.p.m. from -10° to +55°C
- intermediate frequency .......................................................................... 455kHz
- antenna impedance in input ........................................................................ 50Ω
- sensibility (fine signal) ............................................................................... 0.5µV
- local oscillation emission ....................................................<-70dBm (<100pW)
- power supply ........................................................................................230 Vac
Antenna
- maximum power consumption at rest ...................................................... 18mA
ANQ730
- maximum power consumption with activated relay ................................. 20mA
- maximum commutable power at the relay with load in ac/dc ..........60VA/24W
ANQ727
maximum voltage ............................................................................. 30V ac/dc
ANQ727
- excitation delay/dropout delay ...............................................................150 ms
SERIAL NUMBER
ZVL114.04
The S46 series conforms to the essential requirements of the directive 99/05/CE
and the technical reference standards have been applied. This product has been
tried and tested in the manufacturer's laboratory, during the installation of the pro-
duct follow the supplied indications carefully.
- the wires are fastened down using a cable clamp;
- once the wiring is complete the holes through which the wires have passed have
been sealed using silicon;
- the holes which are not used are sealed by inserting the sealing caps "D".
• Only low voltage circuits may be wired to the external circuit binding posts.
Receiver antenna installation
Minimum and maximum range of the radio controls. "Range" is intended to mean the
working distance, measured in free space, between the receiver and the transmitter with
the antenna installed.
The range is therefore closely linked to the technical characteristics of the system (power
and sensibility) and varies according to the characteristics of the site in which the system
is located. It therefore follows that to obtain the best results from the radio control the
installation sites for the receiver and the antenna should be carefully chosen.
It is not possible to install 2 receivers at a distance of less than 1,5 m from each other. It is
good practise to position the receiver away from computer systems, alarm systems and
other possible sources of disturbance.
(A bad choice of positioning could compromise the performance of the receiver).
Antenna
The installation of the antenna is fundamental; connected to the receiver it represents
the reception point for the radio control. When installing the antenna the following points
should be observed:
- Only use a tuned antenna connected to the receiver using a coaxial cable RG58
(impedance 50Ω) with a maximum length of 15 m;
- The antenna should be positioned out of doors in the highest possible point, visible and
away from metal structures.
Note: If for some particular reason it is not possible to fit an antenna, a reasonable
performance can be obtained by connecting a 2,5 m piece of single pole conductor wire
(Ø1 mm) to the receiver.
TRANSMITTERS (fig. 3-4)
In the transmitters each key corresponds to a different channel, with the sole excep-
tion of the two key transmitters where it is possible to have the same channel for
both keys. (single-channel operation).
For double-channel operation which can be obtained using the second key, set the
two-way dip-switch, located separately from the nine-way user code dip-switch on
the printed circuit board.
Once the transmitter's functions have been programmed or recognized, make sure
that every relay strip in the outdoor receiver corresponds to the desired function.
PROGRAMMING THE TRANSMITTER USER CODE
The transmitters and receivers are supplied with a block of 3-way dip-switches with
which to program the digital codes for each system. Programming can be carried out
more than once, even after the installation, thus ensuring the total secrecy of the user
code. To ensure an exact match between the transmitter and receiver codes when
programming the following should possibilities be taken into consideration:
For 2 and 4 key transmitters coupled with receivers with up to 4 channels. Set the
same code in both the receiver and the transmitter using all the 9 available DIPS
(19683 possible combinations). It is important to remember that the receivers can
only respond to one command at a time.
IT FOLLOWS THEREFORE THAT MULTIPLE FUNCTIONS CANNOT BE USED CON-
TEMPORANEOUSLY.

TECHNICAL SPECIFICATIONS

TRANSMITTERS
- carrier frequency tolerance ...................................30p.p.m. from -10° to +55°C
- band width ...................................................................................10kHz/± 5kHz
- apparent radiated power ...........................................-10...-7dBm (100-200µW)
- apparent power harmonic products ....................................... <-64dBm (<1nW)
- power output adjacent channel (± 10 kHz) .........................<-37dBm (<0.2µW)
- modulation ...........................................................................................AM/ASK
- signal modulation .................................................................... PCM, 1.3ms/bit
- power supply (Alkaline battery GP23A) .......................................... 12V ± 10%
- maximum power consumption ..............................................................<38mA
- operating temperature range ....................................................... - 20... +70°C
- relative humidity........................................................................................<95%
SERIES
MODEL
S46
230 Vac
21-09-2001
DATE

Publicidad

loading