Uniteck UNIMOS 80/24.2 Manual De Instrucciones página 15

Ocultar thumbs Ver también para UNIMOS 80/24.2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PRECAUTIONS BEFORE CONNECTION
-
Unimos requires a common ground between the different battery sets and the
alternator.
-
All batteries must be of the same voltage 12V or 24V.
-
Make sure that the charging source is switched off and remains switched off during installation.
-
Install your Unimos separator as close as possible to the charging source and batteries.
-
It is recommended to use suitable cable cross-sections for the different power connections and
to limit the lengths as much as possible.
Advice on the minimum cable cross-section to be used:
Charging current
< 50 A
Between 50 and 100 A
Between 100 and 150 A
Between 150 and 250 A
> 250 A
REPLACEMENT OF A DIODE BATTERY ISOLATOR BY A UNIMOS BATTERY ISOLATOR
To replace a diode battery isolator by a UNIMOS battery isolator, a common ground between the
different battery sets and the alternator is needed.
Diode battery isolator
Starter
Battery
Cable length < 2 m
16 mm
2
25 mm
2
35 mm
2
50 mm
2
70 mm
2
Battery
common
ground
www.uniteck.fr
Length 2-5 m
25 mm
2
35 mm
2
50 mm
2
70 mm
2
90 mm
2
UNIMOS battery isolator
Starter
Battery
EN
15/28

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Unimos 120/24.2Unimos 160/24.3Unimos 200/24.3

Tabla de contenido