Descargar Imprimir esta página

Honeywell MICRO SWITCH GSX ISSUE 8 Instrucciones De Instalación página 18

Publicidad

MICRO SWITCH™ GSX Series
Designation and
Rated Operational Current Ie (A) at Rated Operational Voltage Ue (V)
Utilization Category
24 V
AC15
A300
AC15
A500
AC15
A600
DC13
Q300
2,8 A
Rated thermal current (Ith)
Sealing
Rated impulse withstand (Uimp)
Pollution degree
Rated insulation voltage (Ui)
Operating temperature range
Short-circuit protective device (type/maximum rating)
Expected mechanical life
Conditional short-circuit current
Electrical rating for gold-plated contacts
• Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC.
• Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function.
• Sira 08ATEX1073X
• IEC Ex SIR 08.0021X
• IEC/EN60947-1, IEC/EN60947-5-1.
• MCTF (Mechanical Life): > 1,000,000 Cycles with Single Sided Confidence Limit of 100%. *
• MCTF (Electrical Life): > 25,000 Cycles with Single Sided Confidence Limit of 100%. *
Highest SIL Capability: SIL3 (HFT:1), IEC 61508-2: 2010
Proof Test Interval: 1 Year
18
sensing.honeywell.com
120 V
240 V
6 A
3 A
6 A
3 A
6 A
3 A
0,55 A
0,27 A
* (* APPLICABLE ONLY FOR GSX***A** - * THROUGH GSX***D** - *)
380 V
480 V
1,9 A
1,5 A
1,9 A
1,5 A
10 A
IP67; NEMA 1, 3, 4, 12, 13
2500 V
3
300 V, 500 V, 600 V
-40 °C to 70 °C [-40 °F to 158 °F]
Class J fuse (10 A/600 V)
1,000,000 operations
1000 A
10 µA to 100 mA, 1 Vac/Vdc to 50 Vac/Vdc
50032072
Issue 8
500 V
600 V
1,4 A
1,4 A
1,2 A

Publicidad

loading

Este manual también es adecuado para:

50032072