Preset programmes
Programme
Temperature °C
1
250
2
350
3
450
4
550
5. Memory function [S]
The values selected for the four programmes can be
changed and memorised at any time. To do this, first press
the programme button "P"
programme you wish to change. Set the temperature and
airflow rate you require. Memory symbol
flashes to indicate that the user programme selected has
been changed. To memorise this setting in the user pro-
gramme selected, press and hold down the programme
selector button. The memory symbol continues to flash for
approx. 2 sec. The settings entered are saved once the
memory symbol stays on all the time. To return to normal
operation, press the programme button until the programme
symbol disappears from the display.
Temperature measurement on the workpiece
We recommend the STEINEL HG Scan PRO temperature
scanner (Prod. No.: 007553) for measuring the temperature
at the workpiece.
Maintenance
3
Fine dust filter
The HG 2620 E is supplied with a fine dust filter
stall it, undo the air inlet and insert the filter. To clean it (with
compressed air), undo screws (a), take off cover and remove
filter.
Repair
Changing the power cord
If the power cord is damaged, it can easily be changed with-
out opening the casing.
Air l/min
approx. 350
approx. 400
approx. 500
approx. 400
11
until the display shows the
on the LCD
a
a
. To in-
3
14
1. Important! Disconnect tool from power supply.
2. Undo screw
and pull off cover cap
d
3. Release cable grip
4. Undo mains terminals
e
5. Pull out cable
.
6. Insert new cable and secure in reverse order
(1. Firmly screw down mains terminals etc.).
Changing the heating element
The plug-in heating element in the HG 2620 E can be
changed in a matter of seconds.
1.
3.
1. Important! Disconnect tool from power supply.
2. Undo guard sleeve screws (Fig. 1).
3. Remove guard sleeve (Fig. 1).
4. Undo 4 screws at the end of the hot air outlet nozzle (Fig. 2).
5. Detach heating element and replace it with a new one
(Fig. 2/3).
6. Firmly screw heating element into place (Fig. 3).
7. Firmly screw guard sleeve back on (Fig. 4).

Other functions

Restart protection
Restart protection prevents the hot air tool from starting after
an interruption in the power supply. The hot air tool is only
ready for operation again after switching it on at the ON/OFF
8
button
.
LOC function
To avoid altering the chosen settings unintentionally, the
HG 2620 E comes with a Lockable Override Control
Function (LOC). To find out how to set the LOC function,
please contact our Service Department on
+44/1733/366-700.