10
5
Specifications (to DIN 16086)
Type
Accuracy class
Mechanical input characteristics
Measuring span
Lower range value
Fundamental resonance frequency of
the diaphragm
Attenuation of the diaphragm
Operating range at 23 °C
Overload limit at 23 °C
Test pressure
Destructive range
During dynamic loading
permissible pressure
permissible vibration bandwidth
(to DIN 50 100)
Material of components in contact
with the measurement medium:
inner surface
pressure connection (tube)
Material of the outer surface
Dead volume with tube
without pressure connection
Control volume
Output characteristics
Nominal (rated) sensitivity
Input resistance
Output resistance
Nominal range of the excitation
voltage
(rms value)
Characteristic curve deviation
(start setting)
Repeatability to DIN 1319
Temperature coefficient of the zero
point, relative to the measuring span, per
10 K, in the nominal (rated) temperature
range
Temperature coefficient of the
sensitivity (measuring span), relative to
the actual value, per 10 K, in the nominal
(rated) temperature range
*)
For other pressure connections (see Options), the dead volume and the material can be found in Section 6
HBM
bar
bar
(abs.)
kHz
1
%
%
%
%
%
%
*)
,
mm
mm
mV/V
Ω
Ω
V
%
%
%
%
10
20
50
12
16
29
70
70
85
stainless steel 1.4542
stainless steel 1.4301
stainless steel 1.4301, PPE
1110
1100
1090
3
(410)
(400)
(390)
3
2
420 (+180/−120)
330 (+90/−30)
0.5...5
0.3
P8AP
P8AP
0.3
100
200
500
0
60
86
134
0,01
0...150
175
175
>200
100
95
95
60
1060
1100
1020
(360)
(400)
(320)
1.5
0.5
0.3
2 ± 2%
370
(+130/−70)
0.5...12
0.3
±0.1
0.2
±0.3
A2079-3.1 en/de/fr/it/es