4 I English
1
TECHNICAL DATA
Type
Dimensions mm
Weight kg (without fasteners)
Single sequential or contact actuation
Recommended operating pressure
range
Maximun permissible operating
pressure
Air consumption per driving
operation
Magazine capacity.
No. of fasteners
Penetration depth setting
Fasteners: plastic bound nail coils
Nail length mm
Nail shank Ø mm
Recommended lubricant
1 litre special oil. Code No.
250 cm3 grasa especial. Code No.
NOISE / VIBRATION INFORMATION
2
Noise characteristic values *
A-weighted single-event emission
sound pressure level at work
station L pA, 1s
A-weighted sound power level
L WA, 1s, d
Vibration characteristic values **
Weighted r.m.s.-acceleration (a)
The noise level when working can exceed 85
dB (A). Wear ear protection!
*
Measured values determined according to
EN 12549:1999.
**
Measured values determined according to
ISO 8662-11:1999.
3
SUPPLIED WITH
1
Coil nailer
1
Tool use and safety instructions
1
Technical data sheet
KMR
4
3528
Only those fasteners specified under technical data
(see 1) may be used.
310/330
When filling the magazine, hold the tool so that the
3.3 kg
muzzle is not pointing towards own body or towards
any other person.
Do not load the tool with fasteners with the safety
5 - 8.5 bar/
yoke or trigger depressed.
0.5 - 0.85 MPa
Firs t take away the rubber ring from the
8.5 bar / 0.85
nail coil . To open the magazine unlock
MPa
the locking lever from the bottom magazine
2.6 l at 6
(20 100) by pressing. Hold the nailer such that the
bar / 0.6 MPa
magazine is horizontal and fully open. Using the
knurled nut (20008), the support plate is set for the
used nail length according to the scale graduations.
250-300
Insert the nail coil from the top. Take care that the
yes
beginning of the coil protrudes approx. 2 cm (0.8 inch)
from the magazine. The magazine is locked simply by
latching it. Ensure that the nail coil is not restrained
50-80
in its movement. Open the guide flap (30 200), insert
2.5-3.1
the nail coil start and close guide flap.
9 4420
5
68 3868
The penetration depth of the nail head can be
controlled by means of the air pressure. If this is
not satisfactory, the penetration setting offers a
more accurate adjustment of the penetration depth.
3528
Adjustment is only possible in the unpressurized
condition.
Change the penetration depth by turning the setting
ring (55112) using the Allen key supplied or a pin with
82 dB(A)
max. diameter of 4.5 mm (0.18 inch).
Turning from hole to hole in the setting ring causes a
95 dB(A)
change by 0.2 mm (0.008 inch). The setting distance
is 6 mm (0.236 inch). The setting can be judged by the
distance of the screw head in relation to the contact
3 m/s2
face on the nosepiece (30 101) (max. distance =
6 mm (0.236 inch), largest penetration depth of the
nail).
6
Balancer for 30-55 N (3.0-5.5 kp),
cable travel 2.0 m (6.5 ft)
Suspension
Safety yoke with large support plate
FILLING THE MAGAZINE
FIL PENETRATION DEPTH SETTING
ACCESSORIES
3528
Code No.
28 6478
71 3287
73 0248