2. OPERATING TRANSMITTER:
Your DC brushless motor is equipped with an automatically learned type remote control. Restore power to ceiling fan and test the transmitter as
below for proper operation:
A. I, II, III, IV, V and VI button:
These six buttons are used to set the fan speed as follows:
I = minimum speed
II = low speed
III = medium low speed
IV = medium speed
V = medium high speed
VI = high speed
B.
button:
This button turns the fan off.
C.
Reverse button:
This button is to control fan direction
D.
Light button
This button are controlled by pressing the light button. Tap button quickly to turn light off or on. Push the button once and release to turn the
light on to full brightness. Hold the button down to increase or decrease light brightness. Release the button at the desired light brightness and
that setting will be remembered the next time the light is turned on. The pre-set brightness can be changed by holding down the light button
again until the new desired brightness is reached.
E. SET code setting button:
Follow the below steps to set the remote control:
The auto learning function will only mandate within 60 seconds when turning the fan's AC power ON.
Pairing Process
With the fan's power off, restore power to the fan. Press and hold "SET" button for about 5 seconds and release. If optional light kit is installed,
the light kit will flash twice and the signal light on the wall control will come on when the button is pressed. The fan has completed the pairing
process with the wall control and is ready for use.
NOTE: A single fan can be controlled with as many as 3 wall controls in one room. Every control will need to repeat the pairing process based
on instructions above and all controls must be within 30 feet of the fan.
NOTE: If the self calibration test failed, turn the AC power off; restore power and process the self calibration test again.
NOTE: During self calibration test, the remote is non-fuctional.
NOTE: The learning frequency function and self calibration test will continue to retain the last set frequency and calibration set even when the
AC power is shut off. If the frequency is changed the self calibration test will occur again.
F. The Slide "OFF-ON" button turns all power off-on to fan and light.
The receiver provides the following protective function:
1. Lock position: The DC motor has a built-in safety against obstruction during operation. The motor will be locked operation and disconnect
power after 30 seconds of interruption. Please remove obstacles before re-set.
Fig. D
YOUR REMOTE NOW HAS FULL CONTROL OF THE FAN AND LIGHT.
3. TROUBLESHOOTING GUIDE
A. Fails to operate:
a. Power to the receiver?
b. Receiver wired correctly?
B. Won't operate at distance:
If the signal is weak and fails to operate the fan from a distance less than 30 feet,
try repositioning the antenna wire inside the fan canopy for better reception.
.
Signal light
Fig. E
NOTICE!
Your ceiling fan and light kit assembly must meet
the following requirements:
1. Do not use with solid state fans.
2. Electrical rating: 120V / 60 Hz
MAX. motor amps:1.0 A
MAX. light watts: 300 W
(Incandescent only)
For Warranty Information please visit
www.hinkley.com