Programming the activation retard time
0
0
0
0
3
X
X
-
To eliminate an existing retard in the unit, programme once again (according to the
above steps), inserting a retard time of 00
-
In switch mode, if the user code is introduced while the unit is in the activation
retard period (green LED on), the unit is returned to its initial repose status (elimination
of retard, no relay activation).
-
In timer button mode, when the user code is introduced while the unit is in the
activation retard period (green LED on), the programmed retard time restarts
(activation of the relay is thus
Modification of the user code
0
0
0
0
*
X
X
X
X
X
X
X
X
Modification of the programming code
0
0
0
0
#
X
X
X
X
X
X
X
X
1 -
Introduce the programming code. For the first installation (0000).
The red pilot light flashes
2 -
Press the button
3 -
Insert the time you wish to retard the output contact activation <XX>
between 00 (no retard) and 99
The green pilot light flashes twice and switches
From now on the unit will retard
1 -
Introduce the programming code. For the first installation
The red pilot light flashes continuously.
2 -
Press the button <*>. El The green pilot light flashes once and switches off.
3 -
Introduce the new 4-digit user code two consecutive times. Only the
digits from 0 to 9 are
The green pilot light flashes for a moment and the two pilot lights switch off.
The unit has modified the user code and returns to operating mode.
1 - Introduce the programming code. For the first installation (0000)..
The red pilot light flashes continuously.
2 - Press the button <#>. The green light flashes twice and turns off.
3 - Introduce the new 4-digit programming code two consecutive times. Only
digits from 0 to 9 are valid
The green pilot light flashes for a moment and then the two pilot lights
switch off
The units programming code has been modified and it returns to operating
mode
continuously.
<3>.
seconds.
activation.
seconds.
delayed).
valid.
off.
(0000).