PRESSURE TESTING & FLUSHING THE INSTALLATION
Prior to testing, remove cover (1) and
bonnet nut (2) from the body. If this is not a
thin wall mounting, the entire plasterguard
(3) may be removed.
MultiChoice
1
2
3
3
Rough-In Installation
®
Connect top outlet (1) to shower pipe
with proper fittings. Connect bottom outlet
(2) to tub spout pipe with proper fittings.
Pipe (3) between valve body and tub
spout must be a minimum of 1/2" (13 mm)
copper pipe or 1/2" (13 mm) iron pipe in a
straight drop no less than 8" (203 mm) but
no more than 18" (457 mm) long with only
one iron pipe or copper 90 degree elbow
to the tub spout nipple. Do not use PEX
tubing for tub spout drop.
G.
Insert adapter assembly (1) into valve
body. Make sure the adapter assembly
is correctly positioned and is pressed all
the way down inside body. Remove the
retainer (2) from the adapter.