Descargar Imprimir esta página

Imetec Living Air C1-100 Instrucciones Y Advertencias página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7
• Timer - [Fig. F] (only for equipped models)
f1: notches for presetting the time periods.
f2: outer ring.
PLEASE NOTE:
- If the timer has been preset, the selected temperature will be maintained only within the preset time periods.
• Adjustable base - (only for equipped models)
Standard position [Fig. G].
Tilted position: the base can be adjusted to direct warm/cold air upwards. Whilst holding the base steady, slide the motor unit forward
[Fig. H].
I N S T R U C T I O N S
APPLIANCE A
Fan heater function
- Turn the power selector switch [Fig. A] as follows:
position
: Warm air (1100W).
position
: Hot air (2200W)
APPLIANCE B
Fan heater function
- Turn the power selector switch [Fig. E] as follows:
position
: Warm air (1000W).
position
: Hot air (2000W)
- Regulate the thermostat [Fig. C] depending on the temperature that you wish to maintain.
Cool air facility:
- Turn the thermostat [Fig. C] to the maximum temperature MAX.
- Turn the power selector switch [Fig. E] to position
.
Antifreeze function
This function maintains the room temperature at +5°C. When the temperature drops below this level, the fan heater turns on automatically.
- Turn the thermostat [Fig. C] to the antifreeze setting 1.
- Turn the power selector switch [Fig. E] as follows:
position
for gradually restoring the temperature to +5°C.
position
for rapidly restoring the temperature to +5°C.
Imetec-Ion77 Technology (only for models with ionizer)
If your appliance is equipped with an ionizer, the indicator light m will be lit indicating that it is working.
The Imetec-Ion 77 fan heater is equipped with an ionizer, a revolutionary device which reproduces the natural phenomenon of ionization.
The ions generated by the fan heater act positively on the air, revitalising and conditioning it.
APPLIANCE C - C1
Fan heater function
- Turn the power selector switch [Fig. B] as follows:
position
: Warm air (1100W).
position
: Hot air (2200W)
- Regulate the thermostat [Fig. D] depending on the temperature that you wish to maintain.
Ventilator function:
- Turn the thermostat [Fig. D] to the maximum temperature MAX.
- Turn the power selector switch [Fig. B] to position
.
Antifreeze function
This function maintains the room temperature at +5°C. When the temperature drops below this level, the fan heater turns on automatically.
- Turn the thermostat [Fig. D] to the antifreeze setting 1.
- Turn the power selector switch [Fig. B] as follows:
position
for gradually restoring the temperature to +5°C.
position
for rapidly restoring the temperature to +5°C.
F O R
U S E
8
Timer function (only for models with the timer)
The timer function allows you to turn the appliance on and off in the following ways:
• Manual
- Push all the timer notches inwards [Fig. I].
- Turn the power selector switch [Fig. B] to position
,
- Regulate the thermostat [Fig. D] depending on the temperature you wish to maintain.
PLEASE NOTE:
- The timer only works if the fan heater is plugged into a socket.
• Automatic
- Turn the outer ring of the timer clockwise and set it at the current time [Fig. L].
- Push all the timer notches outwards [Fig. M] except for the ones on the time periods when you want the appliance to be on.
- Turn the power selector switch [Fig. B] to position
,
This is a daily timer which repeats its presetting every 24 hours. Each notch equals 15 minutes.
Imetec-Ion77 Technology (only for models with ionizer)
If your appliance is fitted with the indicator light key n for activating the ionizer, you can choose whether to activate it or not. All that is
required to activate the ionizer is to press key n and the indicator light will come on, showing that the ionizer is operating. To deactivate
it, press the key again returning it to the starting position; the indicator light will go out.
The Imetec-Ion 77 fan heater is equipped with an ionizer, a revolutionary device which reproduces the natural phenomenon of ionization.
The ions generated by the fan heater act positively on the air, revitalising and conditioning it.
WALL MOUNTING INSTRUCTIONS
- (only for models with a mounting bracket) [Fig. Q]
The fan heater can be fixed to the wall.
- Fix the mounting bracket to the wall with the two pegs supplied [Fig. N] (the holes must be 16.5 cm apart with a diameter of 6 mm).
- Place the fan heater on the bracket and push it against the wall, so that the bracket catch (o1) hooks onto the back of the fan heater
in line with the grip [Fig. O]. To remove the fan heater from the wall mounting, press the bracket catch as shown by arrow and pull the
fan heater outwards [Fig. P].
APPLIANCE WITH ELECTRO BLOCK
®
CIRCUIT BREAKER
IMPORTANT:
- If your appliance comes with the Electro Block® circuit breaker j, connect it directly to the mains. Never connect it to trailer
plugs, adapters or extension leads. The Electro Block® circuit breaker is equipped with a highly sensitive residual current
circuit breaker that protects the user from earth leakage current for values higher than 10mA.
In order to use the appliance, follow the steps below:
- Plug in Electro Block
®
, then press and release the ON button: the light should go red. Electro Block
- Check that Electro Block
®
is functioning properly by pressing the TEST button: the current cuts off and the red light turns off,
guaranteeing that the circuit breaker Electro Block
®
is in perfect working order.
- After testing, press and release the ON button again: the red light comes on again and the fan heater is ready to work. This test must
be made beforehand every time you use the appliance. In case of irregular or faulty functioning (like repeated operations when the
appliance is connected to the mains, or retarded operations during the Electro Block
Service Centre immediately. When you switch off the appliance and unplug the Electro Block
circuit breaker Electro Block
®
turns off automatically. Any improper use of electrical appliances can be hazardous. A circuit breaker is
not a substitute for basic electrical safety precautions.
USEFUL ADVICE
Whenever you put the fan heater away, make sure that it is protected from dust, to prevent it from entering through the ventilation screen.
, or
depending on the function you wish to activate.
, or
, depending on the function that you wish to activate.
®
is now active.
®
check test), call an authorised IMETEC Technical
®
circuit breaker, the residual current
9
E
N
G
L
I
S
H

Publicidad

loading