2.
Then close the housing using the screws
(01) as soon as possible to maintain
the dessicant capability of the salt bag.
01
3 Technical Data
Mechanical
2xM16 cable glands
Glass window (WxH): 60/95x63mm (2.4/3.7x2.5in)
Internal usable area (WxH): 70x70mm (2.7x2.7in)
Internal usable length with and without accessories:
250mm (9.8in)
Electrical (if the board cabling is present)
Heater Ton 15°C±3°C (59°F ±5.4°F) Toff 22°C±3°C
(71.6°F ±5.4°F)
IN 12Vdc, 1.6Amax
IN 24Vac, 50/60Hz 1.5Amax
Environment
Indoor / Outdoor
Operating temperature with heater: -20°C / +60°C
(-4°F / +140°F)
Certifications
CE EN61000-6-3, EN60950-1, EN50130-4
IP66/IP67 EN60529
3.1 Cleaning
3.1.1 Window and plastic cover
cleaning (PC)
We suggest to use neutral soap diluted with water
or specific products for lens cleaning applied with
a soft cloth.
Avoid ethyl alcohol, solvents,
© 2014 — 2014 Avigilon Corporation. All rights reserved. Unless expressly granted in writing, no license is granted with respect to any copyright, industrial design, trademark, patent or
other intellectual property rights of Avigilon Corporation or its licensors.
AVIGILON, CAPTURE IT WITH CLARITY, HDSM, HIGH DEFINITION STREAM MANAGEMENT (HDSM), THE BEST EVIDENCE and LIGHTCATCHER are unregistered and/or registered
trademarks of Avigilon Corporation in Canada and other jurisdictions worldwide. Other product names mentioned herein may be the unregistered and/or registered trademarks of their
respective owners. ™ and ® are not used in association with each trademark in this document.
ES-HD-HWS-SM
hydrogenated hydrocarbide, strong acid
and alkali. Such products may irreparably
damage the surface.
3.2 Disposal of waste materials
This symbol mark and recycle system
are applied only to EU countries and not
applied to the countries in the other area of
the world.