10. Specifications
Specifications
Temperature error at 0 ... 80 °C
[32 ... 176 °F]
Long-term stability at reference
conditions
Reference conditions
Ambient temperature
Atmospheric pressure
Humidity
Power supply
Mounting position
Time response
Settling time
WIKA operating instructions pressure transmitter, model S-10
Mean temperature coefficient of zero point
Mean temperature coefficient of span:
≤ ±0.2 % of span/year
15 ... 25 °C [59 ... 77 °F]
860 ... 1,060 mbar [86 ... 106 kPa/12.5 ... 15.4 psig]
45 ... 75 % r. h.
DC 24 V
Calibrated in vertical mounting position with process connection facing downwards.
≤ 1 ms
≤ 2 ms for output signal DC 0.5...4.5 V ratiometric and measuring ranges < 0.4 bar [< 5.8 psi]
Measuring ranges ≤ 0.25 bar [≤ 3.6 psi]:
≤ 0.4 % of span/10 K
Measuring ranges > 0.25 bar [> 3.6 psi]:
≤ 0.2 % of span/10 K
≤ 0.2 % of span/10 K