INSTRUCTIONS FOR USE
FULL LED will turn on.
• STEP 6: Pulsed current cycle. Pulsed battery maintenance cycle (over long periods).
ATTENTION: Because of the high voltage reached during this charging cycle, the battery recovery
process must be performed with the battery disconnected from the motor vehicle. Recovery
with the battery connected to the motor vehicle may result in damage to the motor vehicle's
electronics.
Minimum battery voltage
If the initial voltage of the battery is lower than 2.5V, the battery cannot be recovered.
B) "Flash" supply and charging mode: "Amperage"
Preset supply current bands:
Flash 10A: supply current set to 10A
Flash 30A: supply current set to 30A
Flash 60A: supply current set to 60A
Flash 120A: supply current set to 120A
Preset charging bands to select connected battery (output current adjusted automatically)
Charge 10Ah – 100Ah: Supports batteries from 10Ah to 100Ah
Charge 100Ah – 300Ah: Supports batteries from 100Ah to 300Ah
Charge 300Ah – 600Ah: Supports batteries from 300Ah to 600Ah
Charge 600Ah – 1200Ah: Supports all batteries from a minimum of 600Ah to a maximum of 1200Ah.
C) "Flash" supply voltage and supported batteries: "Volt / Batt."
Preset supply bands:
13.8V: Supply voltage set to 13.8V
14.4V: Supply voltage set to 14.4V
14.8V: Supply voltage set to 14.8V
Preset battery types:
Wet: Acid electrolyte batteries. Charge end at 14.4V
Agm: Flat plate Agm batteries or Optima type spiral batteries. Charge end at 14.7V
LiFePO4: LiFePO4 batteries
Saving settings
The battery charger saves the settings on the front control panel. In the event of an accidental power
loss or voluntary power off, when the charger is restarted, it will restart with the latest saved settings.
With the battery charger set to the FLASH mode, the work cycle will resume automatically when the
power supply is restored.
Whereas in the CHARGE mode, the screen will display the error message ER01, and the START/STOP
key will have to be pressed, to resume the normal charge cycle.
Battery testing
The tests within the operating modes may terminate with the signalling of some errors.
• Damaged Battery: the "Fault" LED switches on and the "Start / Stop" LED switches off, and the charger
enters Stand-by mode. The display shows the message "Errx", where 'x' is the number corresponding
to the cause of the error (see Table 1). Single two second audible warning.
• Polarity reversal: the "Reverse" LED switches on, and the display shows the message "Err7" with a two
second audible warning.

ERROR CODES

The errors that may be reported are described in Table 1.