CLEANING THE DUST COLLECTION SYSTEM
ATTENTION! Empty the dust collection compartment (11A) and clean the
filtering system (11B, 11C) after every use.
NEVER fill the compartment above the permissible MAX level (11D).
•
Clean the dust collection system following the instructions below and paying attention
to the figures in the illustrative guide.
•
pull the dust collection system release lever (14) and detach the dust collection system
(11) [Fig. F1].
•
extract the filtering system (11B and 11D) [Fig. F2] and empty the contents of the dust
collection compartment (11a) [Fig. F3].
•
separate the filter protection mesh (11B) from the cyclone filter (11C) by pulling its rim
[Fig. F4] and clean them both by shaking and brushing the dust off with care. to do so,
use a soft brush to prevent any damage.
If suction power does not increase after cleaning the dust collection compartment (11a)
and the filtering system (11B and 11C), replace filter (11C) with a new one.
NOTE:
•
Replace the filter in the event it is damaged or impossible to clean.
•
Replace the filter at least once a year.
•
Failure to clean or replace the filter will make the manufacturer's warranty null
and void.
put the filtering system (11B+11C) back inside the dust compartment (11a) and reattach it
to the sweeper body, being careful to hook it onto the suitable bottom fitting and making the
dust collection system release lever click (14).
STORING AND CARING FOR THE PRODUCT
if the appliance is not used, take the feeder out (7) and store the appliance in a dry and
dust-free place.
PROBLEM
the appliance does not
go on.
the appliance switches
off during use and does
not switch back on again.
14
TROUBLESHOOTING
• Check whether the battery is charged.
• make sure the plug is disconnected (7) from the socket. When
the plug is connected to the socket, a battery protection
system will stop the appliance from starting up.
• make sure that the on/oFF switch (8) has been pressed.
• the battery is flat. recharge the battery.
• if the problem continues, the battery needs to be replaced.
contact a technical assistance centre.
SOLUTION