Tamper
The reader is provided with a tamper facility. When connected
to the bus, tamper data is transmitted to the Advisor Master
with system data.
Reader menus
Enter via the Installer menu and select the menu "Remote
Devices", then select "RAS".
The following options are available:
1.
Tamper option: Enable/disable (default enabled)
2.
Reader Address: Changing reader address (1 to 16),
default = 16
3.
RTE (egress): Enable/disable the request to exit and open
collector (default disabled)
4.
Backlight option: Permanent/Access only (default Access
only)
5.
Buzzer option: enable/disable reader buzzer (default
enabled)
6.
Restore factory defaults
Reader wiring
Table 1: Reader wiring
Red
+12V
Positive 10 to 30 V
Black
0 Volts
DC supply ground
White
D+
RS-485 Data +
RS-485 Data −
Green
D−
Yellow
RTE
Request to exit button
Violet
OC
Open Collector output used to control a door
relay
Bare wire
Shield
Safety shield
Spare wires are not used.
Use WCAT54 cable to extend the standard shielded cable.
Make sure the shield is properly connected.
Cable length depends on the bus configuration.
Reader LEDs
Table 2: Reader LEDs
LED pos.
Colour
Left
Green
Red
Green / red flashing
Green flashing
Middle
Orange
Right
Red flashing
Specifications
Number of card combinations
Supply voltage
Supported card types
2 / 22
supply, 80 mA
Description
System disarmed
ATS125x: System armed
Valid card presented
Door open time
ATS4000: System not ready
ATS125x: Always on
Alarm
15
72x10
10 to 30 V
ACT4xxE, Mifare Classic
(7 Byte UID), Mifare DESfire
EV1, Mifare Plus, Mifare
Ultralight
Connectivity
Cable
Normal operating current
Maximum operating current
Open collector output (OUT terminal) 14 V
LED
Wireless operating frequency
Maximum power output
Material of design housing
Dimensions of housing (H x W x D)
Field strength
Pry-off tamper
Operating temperature
Storage temperature
Relative humidity
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation, Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Version
This document applies to ATS1160N and
ATS1161N hardware version 2.0 or later.
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE
AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
EN 50131-1 System requirements
EN 50131-3 Control and indicating equipment
Security Grade 3, Environmental class III
Tested and certified by VdS Schadenverhütung
GmbH.
Protection class
IP67
Carrier Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of all applicable rules
and regulations, including but not limited to the
Directive 2014/53/EU. For more information see:
firesecurityproducts.com
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
P/N 1070070 (ML) • REV E • ISS 09MAR21
ATS data bus
LIYY 2 m
50 mA at 13.8 V
80 mA at 13.8 V
max. at 50 mA max.
Tri-color
13.553 to 13.567 MHz
42 dBµA/m at 10 m
Plastic
140 x 44 x 20 mm
According to EN 300 330
Optical sensor
−40 to +55°C
−40 to +55°C
<95%, noncondencing