Descargar Imprimir esta página

Technical Data - Samon TR-EC-CO Guia De Inicio Rapido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB
GENERAL
TR-EC-CO is a sensor designed to measure the concentration
of carbon monoxide (CO) and TR-EC-NO
concentration of nitrogen dioxide (NO
etc. The sensors are of electrochemical type with good
selectivity and high accuracy even at low concentrations.
The detectors provide a linear output signal (4..20mA or 0..10V
DC) proportional to the concentration of carbon monoxide or
nitrogen dioxide.
Choice of output signal is controlled by the jumper (see PCB
layout) with mounted jumper gives 0..10V DC signal output.
Standard measuring range is 0-300ppm for the TR-EC-CO and
0-20ppm for the TR-EC-NO
.
2
MEASURING RANGES AND ALARM LEVELS:
Maximum acceptable gas concentrations are regulated by
hygienic, safety, environmental and construction directives.
Relevant alarm levels depend on application.
Please check local standards and regulations for relevant
values.
LOCATION / INSTALLATION
TR-EC-CO should be mounted on the wall approx 150 cm
above floor level and TR-EC-NO
cm above floor level.
WIRING DIAGRAM
Specifications subject to change.
IS TR-EC-CO_NOx 1306.doc
TR-EC-CO / TR-EC-NO
for measuring the
2
) in the garages, tunnels
2
, on the wall approximately 20
2
2

TECHNICAL DATA:

Model:
TR-EC-(CO)
Gas type:
Carbon monoxide (CO)
Material:
Polycarbonate PC
Method:
Electrochemical
Range:
0-300 ppm
Lifetime sensor:
~ 6 year
Calibration interval:
Automatic zero adjustment,
calibration span once a year.
Power consumption:
20mA
Power supply:
12..28V DC
Output:
4..20mA / 0..10V DC linear
Ambient temp:
-10
Ambient humidity:
0..90% RH
Enclosure:
IP56
Dimensions:
80 x 82 x 86 mm
Weight:
190g
Approvals:
CE, TÜV approved according to
VDI 2053
Model:
TR-EC-NO
Gas type:
Nitrogen dioxide (NO
Material:
Polycarbonate PC
Method:
Electrochemical
Range:
0-20 ppm
Lifetime sensor:
~ 2 year
Calibration interval:
Automatic zero adjustment,
calibration span once a year.
Power consumption:
20mA
Power supply:
12..28V DC
Output:
4..20mA / 0..10V DC, linear
Ambient temp:
-10
Ambient humidity:
0..90% RH
Enclosure:
IP56
Dimensions:
80 x 82 x 86 mm
Weight:
190g
Approvals:
CE, TÜV approved according to
VDI 2053
CALIBRATION
Contact technical support for instructions.
4
o
o
C..+40
C
2
)
2
o
o
C..+40
C

Publicidad

loading

Este manual también es adecuado para:

Tr-ec-no2