Idiomas disponibles

18"
(45.7 cm)
1-13/16"
(4.6 cm)
10-1/4" (26 cm)
1-1/4"
(3.2 cm)
3-1/2"
(8.9 cm)
3"(7.6 cm)
Product Information
Applicable product:
Integral apron, left drain
Integral apron, right drain
Fixture:*
Bathing well:
Basin area, bottom
50" (127 cm) x 24" (61 cm)
Basin area, top
65" (165.1 cm) x 27" (68.6 cm)
Weight
115 lbs (52.2 kg)
To overflow:
Water depth
14" (35.6 cm)
Capacity
72 gal (272.5 L)
* Approximate measurements for comparison only.
Pump:
1-speed
Heater
1.5 kW
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Heater
Locate the outlets behind the whirlpool and within 24" (61 cm)
of the pump.
1012657-1-C
K-1257-HL/HR
72" (182.9 cm)
2-7/8"
1" (2.5 cm)
(7.3 cm)
K-1257-HL
K-1257-HR
V
Hz
120
60
120
60
120 V, 15 A, 60 Hz
120 V, 15 A, 60 Hz
No change in measurements with drain
shown. (K-7166-AF or K-7166M-AF)
20"
(50.8 cm)
1-1/2" OD
Notes
Install this product according to the installation guide.
Floor support under whirlpool must provide for a minimum of
41 lbs/square foot (199.6 kg/square meter) loading.
Floor support under whirlpool must provide for a minimum of
41 lbs/square foot (201 kg/square meter) loading.
The apron must be installed before the finished floor and wall
materials are installed.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions
are nominal.
A
7.5
12.5
2
Recommended faucet area.
36" (91.4 cm)
1-1/4"
(3.2 cm)
1/2"
(1.3 cm) R.
Integral
Flange Detail
Kohler Co.

Publicidad

loading