PASSWORD

The password protects the modification of the Dosing, Utility and Relay menus. It does not block Calibration and Set
up. By default the password is not present and it is therefore possible to access all the programming.
First definition of the password:
Change password:

ENABLE (OPTIONAL)

The enable input (230Vac-110Vac) gives to the pump the consent to dose. In swimming pool plants this input is
connected in parallel with the recirculation pump power supply so that if the filtration is stopped the pump can not dose. In
order not to damage the electronic board, do not connect the enable directly in parallel with the recirculation pump power
supply, but always use a contactor / relay (see installation manual). In the case that your pump has the enable option (see
position B page 18: CONNECTIONS), you can choose to activate this input or not as follows:
If your pump has not included the enable option then it will not be possible to access the "Enable" submenu and the
flashing message "DEA" will appear:
Rev 1.1
In the Set up menu, select "Password" by the cursor and
press ENTER.
Enter the password digit by digit selecting the number by ▼
▲ button and pressing ENTER.
After the selection of the 4th digit, press ENTER to save the
password. Take note of it carefully to not forget it. If it is not
possible to remember the password call the Customer
Service Assistance.
To esc programming and return to measurement, press the
ESC button for 3 seconds.
In the Set up menu, select "Password" by the cursor and
press ENTER.
Enter the old password digit by digit selecting the digit by ▼
▲ buttons and press ENTER.
After entering the 4th digit, pressing ENTER it is possible to
define the new password.
Enter the new password digit by digit selecting the digit by ▼
▲ buttons and press ENTER.
After entering the 4th digit, press ENTER to save the new
password.
Take note of it carefully to not forget it. If it is not possible to
remember it, call the Customer Service Assistance.
If you want to esc the programming and return to
measurement, press the ESC button for 3 seconds.
In the Set up menu, select "Enable" by the cursor and
press ENTER.
Use the ▼ ▲ buttons to select whether to enable ("active")
or disable (deactive) this input and press ENTER.
If you want to esc programming and return to
measurement, press ESC for 3 seconds.