Manual screwdriver
Fit the screwdriver with a suitable fastening accessory, then connect it to the
control unit.
Hold the screwdriver by the handle and apply to the fastener to be tightened.
Select the desired parameters through the control unit.
Press the lever to start the screwdriver.
The screwdriver stops when the preset torque is reached.
For each second of operation, the motor needs to rest for 3 seconds.
Failure to do so may result in motor overheating and damage.
That will be considered as a misuse and the warranty will not be applied.
As the reaction increases in proportion to the tightening torque, make sure that the
screwdriver is in perfect working and the control unit is programmed correctly, to
reduce the risk of injury to the operator as a result of unexpected behaviour of the
screwdriver.
Control and software
Power source by EDU2AE, EDU2AE/HPro e EDU2AE/TOP series.
LUBRICATION
Do not grease too much gears or bearings; a thin coat shall be sufficient.
Grease after 300.000 cycles.

MAINTENANCE INSTRUCTIONS

Maintenance should be performed by qualified personnel only.
Prior to any maintenance task: disconnect the screwdriver.
When disassembling / reassembling the screwdriver, take the following
precautions:
-
Check that the controller is switched off.
-
Disconnect the cable.
According to Directive 2012/19/UE concerning Waste Electrical and Electronic
Equipment (RAEE), this product must be recycled.