TECHNICAL DATA
Dimensions
[mm]
158x172x68
Weight
[g]
720
Input Voltage
[DC] V
11-15
Charging Capability
LiPo/LiFePo
1 - 4 cells
NiMH/NiCd
1 - 10cells
Charge Current
[A]
0.1 - 12.0
Trickle Current
[A]
0 -0.55
Delta Peak
[mV]
1 - 200
Integrated High-Performance Balancer
yes, 2S - 4S
Storage Charge Mode
yes
Discharge Current
[A]
0.1 -20.0 (+ 35 Pulse)
Discharge
LiPo/LiFePo
2.0 - 4.2V/cell
Cut-Off Voltage
NiMH/NiCd
0.1- 1.3V/cell
Specifications subject to change without notice.
CONNECTIONS
Input Connection
(backside of charger, no picture)
11-15V output voltage and a minimum of 12.0A output current. Caution: Be careful with correct polarity!
15A Fuse:
input fuse for protection, only replace with ano-
ther 15A fuse (blue colored housing) and no other types as
these would not offer protection or correct function!
BALANCER CONNECTION
The Pulsar Touch contains an integrated competition balancer for 2S to 4S LiPo- and LiFePo-batteries using XHR balancing
connector. Please refer to drawing (also like that on charger) for correct polarity, basically minus (black wire) is always on the
far right side of the plug as shown on drawing.
The balancer equalises the cells, during charge- and balance-function, which results in higher performance and higher cycle-
life.
Caution: Avoid incorrect connection as in the worst case this may result in damage to the battery and/or charger!
Connection Example 2S:
FACTORY DEFAULTS
The Pulsar Touch comes with 5 pre-set user profiles, but you can also alter those and prepare 5 individual user profiles and
even name them as you like. This means you can customize 5 personal charge profiles individually and store them for later
use. The active profile P1 to P5 and it's name is indicated in the headline of the main menu.
User Profile
P1
P2
CHARGE SETTINGS:
Chg Mode
LiPo
LiFe
Current
6.0A
6.0A
Pack Volt
7.4V / 2S
6.6V / 2S
D-Peak
Trickle
Safety Time
120min
120min
40°C
40°C
DISCHARGE SETTINGS:
Current
20.0A
20.0A
Pack Volt
7.4V / 2S
6.6V / 2S
Cutoff Volt
3.3 cutoff Volt
2.3 cutoff Volt
Cut-Temp
60°C
60°C
OTHER SETTINGS:
Profile Name
2S-LiPo 6A/20A
2S-LiFe 6A/20A
Signal Min
Signal Max
Button Sound
Finish Sound
Finish Melody
LCD Contrast
Temp Scale
Tip: You can always reset to above factory default settings under „CONFIG" function (see separate box).
© LRP electronic GmbH 2014
Autostart Timer
yes, 0-99min
Cycle Mode
yes, adjustable
User Profile Memory
5
Graphical Touchscreen LCD
yes, blue backlit
Acoustic Signal Type
Buzzer
Finish Melody
adjustable
Multi-Protection-System
yes
DC Input Connection
4.0mm connector
Output Connection
4.0mm jacket
Brushless Motor Sensor Port
yes
RX Generator (ESC + Servo Check) yes
Voltage Calibration Mode
yes
USB Connection
yes
:
connect your Pulsar Touch to a suitable DC powersupply with
Output Jacket:
connect battery to be charged to the
4.0mm jacket, using supplied charge wires.
Caution: Be careful with correct polarity!
Balancer Connector:
high-performance integra-
ted Lixx balancer for 2S to 4S packs using EHR balancing
connector.
Temperature Sensor
(optional): connect the
optional temperature probe to measure battery tempe-
rature.
USB Connection:
connect to PCB using the sup-
plied USB-cable. To be used for upcoming firmware
updates and PC software.
Brushless Motor Sensor Port:
a fantastic fea-
ture which allows you to check your brushless motors
sensors and even measure motor rpm! In combination
with the built-in receiver simulator port.
RX Simulator Port:
you can even check speed-
controls and servo's for correct function!
P3
P4
P5
LiPo
LiPo
Linear
6.0A
2.0A
4.0A
3.7V / 1S
11.1V / 3S
20mV
Off
120min
180min
90min
40°C
40°C
55°C
20.0A
2.0A
10.0A
3.7V / 1S
11.1V / 3S
3.3 cutoff Volt
3.3 cutoff Volt
5.4V
60°C
60°C
70°C
1S-LiPo 6A/20A
3S-LiPo 2A/2A
Linear 4A/10A
1000
2000
On
15sec
1
7
°C
Dear Customer,
thank you for your trust in this LRP product. By purchasing a LRP Pulsar Touch, you have chosen a high-performance product
which has the latest technology incorporated including the following High-Tech features:
• Professional Multi-Function System (Charge, Discharge, Cycle, Balance, Motor/ESC/Servo Check)
• up to 12.0A Charge Current
• LiPo • LiFePo • NiMH • NiCd
• Touchscreen Graphics LCD Display
• Multi-Protection-System
Please read the following instructions carefully before you start using your charger. This user guide contains important
notes for the installation, the safety, the use and the maintenance of this product. Thus protecting yourself and avoid
damages of the product.
Proceed according to the user guide in order to understand your charger better. Please take your time as you will have much
more joy with your product if you know it exactly.
This user manual shall be kept in a safe place. If another customer is using this product, this manual has to be handed out
together with it.
TOUCHSCREEN USAGE
As known from LRP, the programme structure is logical and intuitive, therefore most users can familiarise with the usage and
functions without even reading the manual, but it is obviously strongly recommended to read this manual in order to achieve
maximum performance from the PulsarTouch and make best use of all of it's great features.
You can either use your finger or the included plastic pen to use the touchscreen, make sure you only use very light pressure
to activate the functions as too high pressure may damage the display!
Press briefly to jump to next profile (P1 > P2 > P3 > P4 > P5 > P1 ...).
Keep pressed to enter „Profile Name" menu, which allows renaming of the choosen profile (see below).
P1 PROFILE NAME
press arrow to scroll to
the „leftt" (e.g. previ-
ous function)
LINEAR CHARGE
SETUP
press „SETUP" to change the settings of
this function (in this case the function is
LINEAR CHARGE).
Adjusting the settings and hoping through multi-page menu:
P1 CHARGE
Chg Mode
Current
DPeak
Trickle
Safety Time:
NEXT
P1 CHARGE
as [1/2] and [2/2] indicate
Cut-Temp :
in headline, there is a multi-
page menu with more then
one screen. You can hop
through the pages by pres-
sing „NEXT" button.
NEXT
Hidden buttons and how to make them visible again?
To allow more clean screen and more useful information, the buttons will be hidden during many active functions. Simply
touching the screen anywhere will make the buttons visible again. After a short while of no use of the screen, the buttons
will hide again automatically.
Buttons Hidden:
Buttons visible again (after briefly touching screen anywhere):
_XXXX CHARGE
02m30s
Capacity
250mAh
Current
6.00A
Voltage
7.82V
Resistance
0.0mΩ
Temperature
0.0°C
How to adjust the current on the fly?
As known by LRP, the Pulsar Touch's current (charge or discharge) can be adjusted during use. Touch the current value on
the screen, the characters will become inverse (black background) and then use the up/down arrow keys to adjust the current
to your desired value without interrupting the active process.
Important: This change is not saved in memory, the next time you use this function the settings from the memory will be
used.
_XXXX CHARGE
Capacity
Current
Voltage
Resistance
Temperature
NEXT
How to change the profile names?
Keep headline pressed in main menu, this brings you into the function to alter the active profiles name.
You can change the name in several ways, pick the method you feel most
comfortable with.
P1 PROFILE NAME
.
1. straight indicate/write by touching the characters one after the other.
2. hop through the characters by using the right key and confirm the se-
LINEAR CHARGE
You confirm and leave this setting by either pressing „X" symbol in upper
right corner or by pressing „OK" key.
SETUP
START
P1 PROFILE NAME
indicates
which
character in head-
▲
line you have se-
ABCDEFHIJKLMNOPQR
lected for changing
STUVWXYZabcdefghi
jklmnopqrstuvwxyz
0123456789-._'#+/
V
DEL
• up to 20.0A discharge current (+ 35A Pulse Discharge)
• Integrated Balancer for 2S-4S Lixx batteries
• 5 User Profile Memories
.
press arrow to scroll to the
„right" (e.g. next function)
START
The logo (LINEAR CHARGE in this case) indicates
which function is pre-selected.
Press „START" or center symbol to start the function.
[1/2] X
:
Linear
:
4.0A
after accessing the menu with „SE-
TUP" you can select the value which
:
20mV
you may access that value directly
:
Off
by pressing with your finger or pen
or by pressing „SET" button.
90min
Once this line is shown inversed
SET
(black background), you can then
change that value using the up/down
arrown keys.
[2/2] X
You may leave the „SETUP" menu
55°C
again at any time, and the current
values will be stored, by pressing X
in upper/right corner
SET
_XXXX CHARGE
02m30s
Capacity
250mAh
Current
6.00A
Voltage
7.82V
Resistance
0.0mΩ
Temperature
0.0°C
NEXT
STOP
02m30s
Touch current, characters will be-
250mAh
come inverse (black background)-
6.00A
Now use up/down arrow keys
7.98V
to adjust current to your desired
value.
0.0mΩ
0.0°C
STOP
lected character by using the „√" key.
X
indicates new character
you have selected.
OK
•