38/124
6. Close the covers which were previously
opened.
7. Connect to the mains.
8. Insert the NK350/ NK350S network cou-
pler (if used).
9. Insert the modules.
10. Close any unoccupied slots with an ap-
propriate dummy panel (see Table 6).
11. Lay all the connection cables through the
cable duct strip.
12. Check that all the connection lines and
modules are properly connected.
13. Switch the SB356 on at the power
switch.
14. Check that the emergency OFF circuit is
functioning correctly before commission-
ing the tightening system.
15. Configure, program and parameterize the
tightening sequences with the BS350
operating system.
Table 6: Dummy panels
Dummy panel
Type
for
BP351
Servo amplifier
BP352
Controller and
servo amplifier
Bosch Rexroth AGSB356 | 3 609 929 B67/2008-11
8
Operation is not necessary while the system is
running.
Order number
3 608 878 058
3 608 878 060
Operation
CAUTION
Any dirt or liquids penetrating
the device lead to
malfunctions!
Failure to adhere to this may lead to
personal injury or and damage to
equipment caused by
contamination. The interior of the
system boxes have been designed
in compliance with degree of
pollution 2 (equivalent to HD 625.1
and EN 50178).
y
Ensure that the doors are
always closed when operating
the SB356 system box.