Intermatic GRASSLIN thermio essential smart Instrucciones De Manejo página 54

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4.
Place the housing cover on the housing base and tighten the screw on the device housing with the
Phillips screwdriver.
The jumper is in the PID position and you can now set the heating cycle.
ð
5.
Press the reset button (Fig. 1/13) to reset the display.
Setting the heating cycle
6.
To set the heating cycle, press and hold both the top button (Fig. 1/6) and the bottom button
(Fig. 1/9) for five seconds.
"P1:02" and the set symbol (Fig. 1/5) appear on the display.
ð
7.
Press the top button (Fig. 1/6) to increase the number of temperature measurements per hour or
the bottom button (Fig. 1/9) to decrease the heating cycle.
8.
Once you have set the number of temperature measurements, wait five seconds until the display
returns to the current temperature.
The room thermostat measures the temperature in the room at the heating cycle interval you
ð
set.
54

Publicidad

Tabla de contenido
loading

Tabla de contenido