Note: The thermostat does not allow the maximum temperature to be set
lower than the maximum temperature, or lower than the temperature set for
Protection against overheating (see 2.6). This setting also serves as a limit to
protect against floor overheating (which is measured via the Floor Probe), so
that the floor temperature does not go exceed the maximum temperature
limits set.
2.5 Calibration (adjust temperature read by the thermostat to real
temperature)
Press
to navigate between options (Ambient Sensor or Floor Probe).
Press OK to confirm or
2.5.1 Ambient Sensor
Press
+3,0°C). Press OK to confirm and exit. (Default setting: 0,0°C).
2.5.2 Floor Probe
Press
+3,0°C). Press OK to confirm and exit (Default setting: 0,0°C).
2.6 Antifreeze/Overheating Protection setting
2.6.1 Antifreeze Protection (antifreeze protection temperature can
only be set when in heating mode)
Press
(5,0°C to -0,5°C). Press OK to confirm and exit. (Default setting:
8,0°C). If the selected installation type is hydraulic (see 2.2), the
Antifreeze temperature must be above 16°C in order to reduce the
probability of condensation forming in the pipes.
to go back.
or
to select the desired calibration (between -3,0°C and
or
to select the desired calibration (between -3,0°C and
or
to select desired Antifreeze Protection Temperature
39