Note: Antifreeze Protection operates even when the thermostat is "off". This
protective functionality switches the Heating system "on" when the ambient
temperature reaches the minimum temperature set.
2.6.2 Overheating Protection (overheating protection temperature
can only be set when in cooling mode)
Press
temperature (+0,5°C to 35,0°C) press OK to confirm and exit.
(Default setting: 30,0°C).
Note: Protection against overheating operates even when the thermostat is
"off". This protective functionality switches the Cooling system "on" when the
ambient temperature reaches the maximum temperature set.
2.7 Differential temperature
Press
3,0°C). Press OK to confirm and exit. (Default setting: 1,0°C).
2.8 Temperature Monitoring (select the temperature monitoring
sensor)
Press
Ambient Sensor + Floor Probe). Press OK to select or
Note: When the thermostat is "on", Floor Probe is automatically detected. In the event
of a Probe error, an error message will appear on the thermostat.
40
or
to select the desired Overheating Protection
or
to select the desired differential temperature (0,5°C to
to navigate between options (Ambient Sensor, Floor Probe or
to go back.