Troubleshooting - Imer Group MASONRY 750 PLUS Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

16.8
Repairs
- All maintenance operations must be performed
exclusively with the machine switched off, and the power
plug disconnected from the mains.
- If any guards are removed for repairs, ensure they
are correctly refitted at the end of work.
Use exclusively original IMER spare parts; modifications to
parts are strictly prohibited.
17
RESIDUAL RISKS AND SAFETY NOTICES
Although the sawing machine has been manufactured fully in
compliance with current regulations, residual risks exist that
cannot be eliminated and involve the use of appropriate
individual protection devices. The machine is equipped with
notices to indicate the residual risks and how to avoid them.
NOISE HAZARD
Wear ear defenders
HAND CRUSHING/SHEARING HAZARD
EYE INJURY HAZARD
INCORRECT USE HAZARD
Read the manual before operating the
Cutting with water is compulsory
TRAPPING/CRUSHING AND SHEARING HAZARD
Do not remove the guards
Do not touch drive components
IMER INTERNATIONAL S.p.A
Wear gloves
Wear safety glasses
machine
Danger of cutting
ELECTROCUTION HAZARD
Note that the employer is responsible for ensuring his workers
use individual safety equipment.
18

TROUBLESHOOTING

- CAUTION!!! All maintenance operations must be
performed exclusively with the machine stopped off and
the power plug disconnected from the mains.
Problem
An electrical wire in the
Motor fails to start
motor terminal board is
when switch is
operated
An electrical wire in the
The ON switch is faulty
Difficult trolley
horizontal sliding
No cooling water
reaching disc
Disc fails to cut
Motor starts but disc
does not turn
* Operation to be carried out by an electrician
19.Tools supplied
• double-ended wrench CH 10-13
• open ended wrench CH 36
19
Danger - electrical power
Causes
Corrective action
Voltage not reaching
Check the line *
supply line
Electrical socket and
Restore correct
plug are not properly
connection
connected
The power cable from
Change the cable *
the plug to the panel is
cut off
Restore the
connection *
disconnected
Restore the
electrical panel is
connection *
disconnected
Replace the switch *
A fuse has blown
Replace the fuse *
The thermal safety
Wait a few minutes
device has been
and try again
triggered
Dirty runners
Clean the runners
Refer to "cleaning and maintenance of the
cooling system" (par. 17.5)
The disc is worn
Replace with new
Transmission belt not
Tighten the belts
tensioned
Belt broken
Replacing the drive
disc
belt

Publicidad

Tabla de contenido
loading

Productos relacionados para Imer Group MASONRY 750 PLUS

Este manual también es adecuado para:

11888611188862118886311888641188865

Tabla de contenido