EC declaration of conformity
Fault
Pump does not run reliably.
Pump fails to switch off automa-
tically
If you are unable to remedy a malfunction, please call the AL-KO service centre nearest you.
EC DECLARATION OF CONFORMITY
We hereby declare that this product, in the form in which it is marketed, meets the requirements of the
harmonised EU guidelines, EU safety standards, and the product-specific standards.
Product
Domestic water system
Serial number
G3043045
Executive Officer
Hr. Andreas Hedrich
Ichenhauser Str. 14
D-89359 Kötz
Kötz, 26.08.2013
Wolfgang Hergeth; Ma-
naging Director
477 219_b
Cause
Air pressure in reservoir is too
low.
Water shortage inlet side,
Pump sucks in air
Model
HW F 1004 (1000)
HW F 1300 INOX
HW F 1400 INOX
EU directives
2006/95/EG
2004/108/EG
2000/14/EG (13)
Sound power level
EN ISO 3744
measured / guaranteed
HW F 1004 78/81 dB(A)
HW F 1300 INOX 82/83 dB(A)
HW F 1400 INOX 72/73 dB(A)
Solution
Check the air pressure in the
reservoir at the valve (5) and
correct to about 1.5 bar if ne-
cessary.
Unplug the pump, allow to cool
down if necessary
Manufacturer
AL-KO Geräte GmbH
Ichenhauser Str. 14
D-89359 Kötz
Harmonised standards
EN 60335-1
EN 60335-2-41
EN 60335-2-41/A2
EN 55014-1
EN 55014-1/A1
EN 55014-2
EN 61000-3-2
EN 61000-3-2/A1
EN 61000-3-2/A7
EN 61000-3-2/A4
EN 61000-3-3
17