ESG PLUS, ESG PLUS²
7.
OPERATION
7.1
Switching on the ESG Plus
1. Connect the ESG Plus (consider main voltage).
2. Press the ON/OFF switch (1).
The ESG Plus starts.
7.2
Grinding the electrodes
DANGER!
NOTE!
Do not exert too much pressure on
the grinding wheel, since otherwise
the service life of the diamond wheel
is shortened. The strength of the
contact pressure, but even rotation
of the electrode around its own axle
and a small contact pressure of the
electrode to the grinding produce a
high sharpening achievement.
NOTE!
Use a rough diamond wheel during
larger sharpening achievement.
7.2.1
Sharpening electrodes
1. Insert the electrode with the corresponding hole diameter and the desired angle until the grinding wheel is touched.
2. The electrode tip is sharpened evenly by turning the electrode slowly.
NOTE!
[REV. 20200117] OW_ESG_BA_790052773_00__INH-02_EN
Hot dust!
Danger of injury to eyes!
X Do not use thorium-coated tungsten electrodes without a suitable suction devices or a
suitable breathing mask.
X Only work with safety goggles.
X Always wear a breather mask.
Slow and even rotating motion results in a good and exact sharpening result (longitudinal
grind). If the electrode is not turned, then it is flat ground to the selected angle.
Operation
Orbitalum Tools GmbH D-78224 Singen www.orbitalum.com
ENGLISH
1
29