Operation, cont'd.
EMPTY GRAY WATER TANK(S)
Refer to Fig. 1 and Fig. 5.
1. ENSURE universal nozzle (
station! Refer to "Attach Pump to RV" procedure.
TIP For Cleaner Storage: Emptying black water tank first,
NOTICE
allows gray water to cleanse the system.
2. Open gray water tank gate valve (
3. Turn pump on.
4. Do not leave unit unattended.
5. Turn pump off.
TIP: The hose expands as fluid moves to dump station
NOTICE
and contracts when tank is empty.
6. Close gray water tank gate valve
7. Repeat Steps 2-6 for secondary gray tanks.
Gray water bypass is possible if the discharge plumbing
NOTICE
does not flow upward.
PREPARE HOSE FOR STORAGE
Refer to Fig. 1 and Fig. 5.
1. Ensure pump is off.
K2
2. Drain hose (
) by holding at a sloped angle to direct excess
water into the dump station.
TIP For Faster Draining: Leave gray gate valve
NOTICE
open allowing hose to vent and expediting the process.
K2
3. Disconnect nozzle (
K2.3, K2.4
4. Install cap(s) (
(K1)
5. Unhook pump
from power source; remove pump
from RV.
K6
6. Install bayonet cap (
7. Return hose and pump to storage box (
connected to pump.
Sani-Con Model 300 - Portable Tank "Buddy"
K2
) is securely attached to dump
5B
).
(5B)
.
) from dump station.
).
(K1).
) on pump
K7
); leave hose (
Helpful Hints
■
Additional hoses can be purchased from Thetford and used
to extend the length of the evacuation hose. Connect the
hoses using 1.5 " (3.8 cm) barbed coupling with clamp.
■
If you wish to extend the evacuation hose, connect a .75
in (1.9 cm) inner diameter garden hose to the end of the
nozzle.
NOTICE
■
Before storing the hose, make sure that all liquid has drained from
the hose.
NOTICE
Obstruction Removal
Refer to Fig. 1 and Fig. 5.
NOTICE
1. Ensure all contents have been drained from system.
2. Disconnect pump (
pump fuse or disconnecting the battery.
NOTICE
AVISO
AVIS
!
!
!
!
ATTENTION
ATENCIÓN
CAUTION
DANGER
ATTENTION
ATTENTION
ATTENTION
3. Verify all gate valves (
4. Remove pump (
(5B)
5. Remove obstruction from pump (
AVISO
AVIS
NOTICE
!
!
!
!
ATTENTION
ATENCIÓN
CAUTION
DANGER
ATTENTION
ATTENTION
ATTENTION
6. Attach pump to RV's drain outlet (
7. Reconnect the power.
(K1)
8. Operate system using gray water; check for leaks.
K2
)
8
A longer evacuation hose reduces flow rate.
Gray water bypass is possible if the discharge plumbing
does not flow upward.
Be sure to have container available for capturing
system fluid!
K1
4A)
) from power (
Turn off power and remove pump fuse. Once the ob-
struction is removed, there is potential injury to hands or
fingers in the path of the impeller if the power is on!
5B
) are closed.
K1
) from RV's drain outlet (
K1
).
Do NOT remove pump housing. Obstruction MUST be
removed through inlet.
5B
).
by removing the
5B
).
www.thetford.com