As: Association Of Devices; Ek: Setting The Low Pressure Function On Suction; Pk: Low Pressure Threshold On Suction; T1: Low Pressure Delay (Function Detecting Low Pressure On Suction) - DAB E.Sybox mini 3 Instrucciones Para La Instalación Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 368
GB
ENGLISH

5.5.4 - AS: Association of devices

Allows connection/disconnection with the following devices:
• D-CONNECT BOX - Communication gateway.
• DEV Any other compatible devices.
The icons of the various connected devices are displayed on page AS with
below an identifying acronym and the respective reception power.
An icon lit with a fixed light means that the device is connected and working
correctly; a stroked through icon means the device is configured as part of
the network but is not found.
All the devices present over the air are not displayed on this page
but only the devices that have been associated with our network.
Seeing only the devices in your own network allows the operation
of several similar networks existing within the radius of action of
the wireless without creating ambiguity; in this way the user does
not see the elements that do not belong to his pumping system.
From this menu page it is possible to associate and disassociate an ele-
ment from your personal wireless network.
When the machine starts the AS menu item does not show any connection
because no device is associated. In these conditions the message "No
Dev" is shown and the COMM led is off. Only an action by the operator can
allow devices to be added or removed with the operations of association
and disassociation.
Association of devices
Pressing '+' for 5 sec puts the machine into the mode where it searches
for wireless association, communicating this status by the blinking of the
COMM leds at regular intervals. As soon as two machines in a working
communication range are put into this status, if possible, they are associa-
ted with each other. If the association is not possible for one or both machi-
nes, the procedure ends and a pop-up appears on each machine saying
"association not possible". An association may not be possible because
the device you are trying to associate is already present in the maximum
number or because the device to be associated is not recognised. In the
last case repeat the procedure from the start.
The search status for association remains active until the device to be
61
associated is detected (irrespective of the result of association); if not de-
vice can be seen within the space of 1 minutes, the machine automatically
leaves association status. You can leave the search status for wireless
association at any time by pressing SET or MODE.
Disassociation of devices
To dissociate a device belonging to an existing group, go to page AS (in-
staller menu) of the device itself and press the – key for at least 5 seconds.
After this operation all the icons related to the connected devices will be re-
placed the message "No Dev" is shown and the COMM led will remain off.
Replacing devices
To replace a device in an existing group it is sufficient to dissociate the
device to be replaced and to associate the new device as described in the
procedures above.
If it is not possible to dissociate the element to be replaced (faulty or not
available), you will have to carry out the disassociation procedure for each
device and create a new group.

5.5.5 - EK: Setting the low pressure function on suction

Present only in models with Kiwa function.
Sets the low pressure function on suction.
Value
0
1
2

5.5.6 - PK: Low pressure threshold on suction

Present only in models with Kiwa function.
Sets the pressure threshold below which the block is tripped for low pres-
sure on suction.
5.5.7 - T1: Low pressure delay (function detecting low pressure on
suction)
Sets the time when the inverter switches off after detecting low pressure
on suction (see Setting low pressure detection on suction par. 7.6.15.5).
T1 can be set between 0 and 12 s. The factory setting is 2 s.
Function
disabled
enabled with automatic reset
enabled with manual reset

Publicidad

Tabla de contenido
loading

Tabla de contenido