EN
USE - SPECIFIC STANDARDS FOR MULTIFUNZIONE TURBO
HOW TO INSERT THE CONNECTOR
.To insert the connector (26) of hose (20) or iron single-pipe (11 optional), lift the socket (17)
door (if any). Put connector (26) on the opening, then strongly press to the red safety release
click. If the connector generates excessive friction while forwarding, the grease coating the
seals is likely to be exhausted; in case of doubt, grease the seals again with a small brush (Fig. 1).
CONNECTION OF ACCESSORIES
. Components are very easy to engage, put the "male" side (1 in fig.2) into the "female" side
(2 in fig.2), press the red button (3 in fig. 2) and press deeply until the safety clicks.
.To join the large brush (4 in fig. 3) with angle joint (6 in fig. 3) refer to the order specified on
the brush itself, close to the red sliding safety (5 in fig.3). In position 1 (assembly), insert joint
(6 in fig. 3), fasten by taking the red lever (5 in fig.3) to position 2 (locked). To rotate the brush,
take the red lever (5 in fig.3) to position 3 (rotation).
LUBRICATION OF CONNECTORS
It is important to restore the lubrication of connector seals (1 in fig.1) at least once a year, to
prevent them from getting dry or letting steam get out Take mechanical (non food) grease, use
a thin brush to spread a small quantity of it on the seals (2 in fig.1), carefully prevent grease
from penetrating inside the steam duct. If the operation seems too difficult, contact an
authorized technical support centre.