Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English

QUICK GUIDE:

Install the "Wil" boom gate, the control (key selector switch or push button panel) and safety devices (emergency stop,
photoelectric cells, sensitive edges and flashing lights) after which do the wiring following the diagram:
Fig. 1
Prior to turning power on check that the bar is well balanced, adjusting the balancing spring if necessary.
Release the boom gate using the special spanner and check that the bar can move without any effort for the whole length of travel.
Power the unit and check that on terminals 1-2 voltage is 230 V a.c. and on terminals 5-6 it is 24 V d.c.; the LEDs on the active
inputs must turn on and the OK LED must flash at a frequency of 1 flash/second.
Check correspondence of the two FCA and FCC LEDs: when the bar is closed only the FCC LED should turn off and when it is
open only the FCA should turn off.
To exploit the slowing down function it is necessary that the limit switch triggers about 20° before the actual stopping point; if
necessary adjust the two cams until the limit switch triggers at the point required.
Check that all the function switches are in the "OFF" position. This means it is in the manual functioning mode, that is, with the
button pressed. Lock the boom gate with the bar at a 45° angle so it can move freely in both directions. Now give a brief
command pulse on the OPEN input and if the bar does not move in the opening direction proceed as follows:
1 ) Turn power off to the boom gate
2 ) Unplug the "MOTOR" connector and replug it after it has been turned 180°
3 ) Unplug the "LIMIT SWITCH" connector and replug it after it has been turned 180°
See if rotation direction is right, repeating the procedure described above.
Temporarily adjust the STOP_AMPERE and WORKING FORCE trimmer to the maximum of the travel, PAUSE TIME to minimum
and SLOWING DOWN FORCE to halfway travel. Now try and carry out a complete manoeuvre until the limit switch is reached
and the subsequent stopping point and then try the manoeuvre in the opposite order.
Set the FUNCTIONS dip-switches as required:
Switches 1 - 2
Off Off =
On Off =
Off On =
On On =
Switch 3
On
Switch 4
On
Switch 5
On
Switch 6
On
Switch 7
On
Switch 8
On
Switch 9
On
Switch 10
On
Adjust the two trimmers WORKING FORCE and SLOWING DOWN FORCE until obtaining the force and speed required during,
respectively, the travelling and slowing down phases; only now adjust the STOP_AMPERE trimmer until the triggering threshold
required is obtained.
If in the automatic functioning mode, adjust the PAUSE TIME trimmer as wanted.
12
Do not install the "Wil" boom gate without having read all the instructions!
STOP
PAUSE
AMPERE
TIME
FUNCTIONS
OK
FCA
FCC
"Manual" movement (Man Present)
"Semiautomatic" movement
"Automatic" movement (Automatic Closing)
"Automatic + Always Closes" movement
=
Condominium Functioning Mode
=
Cancels STOP in the Step-by-Step cycle
=
Pre-flashing
=
Flashing also in Pause
=
Recloses immediately after Photocell (only if on Automatic)
=
Safety device (Photocell) also in the opening phase
=
Bar open indicator becomes traffic light in the "one-way" mode
=
Functioning in the "Traffic light in both directions" mode
SLOWING
DOWN FORCE
WORKING
44
ANTENNA
FORCE
43
42
2ND CH
RADIO
41
CLOSE
15
CLOSE
OPEN (TIMER)
14
OPEN (TIMER)
13
STEP-BY-STEP
STEP-BY-STEP
12
PHOTOCELL 2
PHOTOCELL 2
11
PHOTOCELL
PHOTOCELL
10
STOP
STOP
9
BAR OPEN INDICATOR
8
COURTESY LIGHT
7
COMMON
+ (24v)
6
24 Vcc
max 200 mA
5
- (0 v)
LUCY 24 Vcc
4
+
max 25 W
3
-
2
230 Vac
50-60 Hz
1