Applying the seal
Important - The figure below shows how the seal must be attached all around the perimeter.
This cook top has been designed for non-professional, domestic use.
Coupling two or more Domino cook tops
Cut out the work top to allow for the flush mounting of two or more Domino cook tops.
First of all, place the steel supporting element (E) provided in the package in position, then insert the cook top (G) as illustrated in
the figure below., Insert the second cook top (F) in the remaining space.
Together with the seal on the two Domino cook tops, the steel support will ensure that the top is watertight.
The Domino cook tops are fixed to the work top using the kit of brackets provided.
F
G
2.
Electric connections
Check the details given on the nameplate situated on the underside of the cook top, then make sure that the rated mains voltage
and power available are suitable for its operation.
Before making the electric connections, check the efficiency of the earthing system. Earthing of the cook top is compulsory by law.
The manufacturer will accept no liability for any personal injury or damage to property deriving from failure to comply with this
requirement.
For models without a plug, fit a standard plug capable of withstanding the specified load on the power cord. The cord's earthing
conductor is colored yellow and green. The plug must be accessible.
If you prefer to make a fixed connection to the mains, insert an all-pole circuit breaker with a breaking gap of at least 3 mm
between the cook top and the mains.
To connect the cook top power cord, loosen and remove the cover on the terminal block in order to access the contacts inside.
Make the connection, blocking the cord in place with the cable clamp provided and then close the terminal block cover again
immediately.
If you have to change the cord, the earthing (yellow / green) conductor must always be 10 mm longer than the line conductors.
Use only rubber cable type H05RR-F; the cross-section of the wires must be 3x1.5 mm.

DECLARATION OF CONFORMITY

This appliance, in the parts intended to come into contact with food, complies with the requirement of the Directive 89/109 EEC
and the D.L. Implementing No. 108, 25/01/92; replaced by Regulation 1935/2004/EC.
This appliance complies with the requirement of the European Directive 73/23/CEE and 89/336/CEE, replaced by 2006/95/CE e
204/108/CE and following modifications and also to the European directive No. 93/68/CEE.
ATTENTION: If you need to replace the power cord, be sure to respect the following code-colour during the
connection of individual wires: