Electrical Outlets
Connect up to eight (8) HEPA 700s on a 15-amp circuit on
the lowest speed; four (4) on the highest speed.
COMMAND HUB: HOME
On/Off. Switches unit on or off.
Speed control to adjust blower speed.
Menu. Select to view system info, service, error
messages, wireless setup and other information.
MAINTENANCE
About the filters
IMPORTANT: Use Legend Brands HEPA 700 filters only
(see Filter Options below). Using other filters will reduce
filtration effectiveness.
Regularly check and replace the prefilter(s) and HEPA
primary filter as needed. Control panel indicates when
the HEPA primary filter needs to be replaced. Do not
attempt to clean and reuse filters.
NOTICE: When using the HEPA 700 on remediation
projects, change BOTH filters after every job. Dispose of
contaminated filters per local, state and federal
regulations.
Replacing the Prefilter
When using the unit in environments with a high volume of
airborne particles, the prefilter should be replaced more
frequently to help preserve the life of the HEPA filter.
1. Lay unit on its back and release the four (4) buckles. Lift off
the filter door.
2. Remove the prefilter from the filter door and discard.
3. Insert new prefilter into filter door. Ensure that the prefilter is
seated properly on the retention tabs.
4. Replace filter assembly on unit and reattach four buckles.
Filter Options
Air Filtration Applications:
Water loss air filtration and mold
remediation*
Standard air scrubbing. For high particle
loads, such as construction or remodeling sites.
Odor control and air filtration. For removing
volatile organic compounds (VOCs), fumes from
paint and paint thinners, and many other
noxious odors, eg, from food, sewage, etc.
Smoke particulate and odor removal. Paper
prefilter and HEPA filter remove particulates
and carbon filter adsorbs odors.
See Owner's Manual for asbestos remediation guidance.
For parts and service, contact your local dealer or Legend Brands, 15180 Josh Wilson Rd., Burlington, WA 98233
Live Chat: Info.legendbrands.com | Email:
125385D HEPA 700
Changing Filters
Secure replacement prefilter(s)
into notched tabs (×4)
Filter cover
Prefilter Option 2:
Two 1-inch filters
Replacing the HEPA Primary Filter
IMPORTANT: Performance is reduced when a non-Legend
Brands primary filter is installed. For maximum filtration
performance, use only Legend Brands filters. Do not clean and
reuse the HEPA filter. Always replace the prefilter when
replacing the HEPA filter.
1.
Lay unit on its back and release the four (4) buckles. Lift
off the filter door.
2.
Remove the prefilter from the filter door and discard.
3.
Replace HEPA primary filter, handling it with care, as filter
is easily damaged. Do not use a filter that is damaged.
4.
Place new prefilter(s) in filter door. Replace filter cover and
lock the four buckles securely.
Regulatory approvals - ATWINC3400-MR210CA modules:
United States/FCC ID: 2ADHKWINC3400
Canada/ISED:
Prefilter(s)
Removes larger
particulates – protects
primary filter
2-in. MERV 8 Pleated
Paper Filter
#125026 (6 pk.)
1-in. MERV 8 Pleated
Paper Filter
#125029 (12 pk.)
Service@legendbrandsrestoration.com
2
Prefilter Option 1:
One 2-inch filter
HEPA filter
Filter cover
buckles (×4)
o
IC: 20266-ATWINC3400
o
HVIN: ATWINC3400-MR210CA
o
PMN: Wi-Fi and Bluetooth Module
Specialty Prefilter
Primary filter (HEPA)
Carbon removes
Removes fine particulate
VOCs and odors
down to .3 microns
1-in. Activated
Carbon Filter
#125027 (4 pk.)
| Phone: 800-932-3030
HEPA filter
locking tabs
HEPA Filter
#124966 (1 pk.)
#125028 (8 pk.)
HEPA Filter
#124966 (1 pk.)
#125028 (8 pk.)
Legend Brands, Inc.

Publicidad

loading