GF 582 Manual De Instrucciones página 41

Ocultar thumbs Ver también para 582:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Type „Radial installation and removal":
 Loosen the coupling nut and slide it on the intended pipe end.
 Connect the connection parts with the pipe ends. For instructions concerning the
different connection types, see planning fundamentals.
 Put pressure reducing valve type 582/pressure retaining valve type 586 between
the connection parts.
 Tighten the coupling nuts by hand.
„Spigot ends":
 If adapted to flange version, observe the tightening torques of the flanges, see
„Georg Fischer planning fundamentals".
In order to protect against soiling and premature wear and tear by erosion,
we recommend installing a strainer on the inlet side of pressure reducing
valve type 582.
Adhesive joint
 Only join identical materials.
 After the curing time of the joint has elapsed, rinse the pipe section as quickly as
possible with pressure-less water, see Chapter „Jointing techniques" in the
„Georg Fischer planning fundamentals"
Welded joint
 Only join identical materials, see Chapter „Jointing techniques" in the
„Georg Fischer planning fundamentals".
Instruction manual
41

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido