TF = Fixed towel warmer for permanent installation.
Supplied complete with connection cable /with plug/
and wall brackets with screws.
Supply voltage 230 V AC.
Enclosure class IP 44.
TFR = As TF, but with adjustable surface temp. 38-60ºC.
TT = Swivelling towel warmers for permanent installation.
Supplied complete with connection cable /with plug/
and wall brackets with screws.
Supply voltage 230 V AC.
Enclosure class IP 44.
TTR = As TT, but with adjustable surface temp. 38-60ºC.
INSTALLATION
Assembly and connection
Fit the towel warmer on a vertical wall using the supplied
screws. See Figures 1-6 for correct positioning. The minimum
distance A shown in Figures 3 and 4 is 60 cm. The minimum
recommended distances from adjacent boundary surfaces are
shown in fig. 5 and 6. The coupling box and switch/knob must
be at the bottom of the towel warmer.
The wall brackets for the TF/TFR model can be repositioned
to take account of any tile joints, etc.Tighten the brackets from
the rear using the screw at the centre of the bracket before
fitting the towel warmer to the wall; see fig. 3A.
The lower wall bracket of the TT/TTR model can be adjusted
vertically within the range shown in fig. 6.The wall brackets are
assembled at the factory to provide sufficient swivel resistance
and do not normally require adjustment.
Any necessary adjustment can be made with the screw inside
the bracket, as shown in fig. 3A.
Towel warmer with connection cable and plug
Connect the towel warmer's connection cable to an earthed
wall socket with the plug.
Towel warmer with connection cable without a plug
Connect the towel warmer's 3-core cable to a suitable termi-
nal box as follows:
Brown wire
= Live
Blue wire
= Neutral
Green/yellow wire = Earth
Model TF/TFR with concealed connection
The TF/TFR model can be installed with concealed connection
as an alternative (not the TT/TTR model). The centre of the
wall outlet for the connecting wires can be seen in fig. 7. The
supplied backing washer can be used here.
The connection box must be modified for installation with
concealed connection. Start by removing the lid of the
connection box by undoing the two screws which hold the lid
in place.Then disconnect the installed connection cable.
Remove wires A on the heating element and release the insert.
Remove nut C completely, using the supplied 21 mm hexagon
socket, and rotate the under part of the terminal box so that
bushing D faces the wall, see fig. 8 for TF and 9 for TFR, and
then tighten nut C securely.
Installation with concealed connection without
backing washer
Position the connection box so that the hole in bushing D
centres the connection cable, and then mark the screw holes
on the wall brackets. Install the towel warmer.
Installation with concealed connection with
backing washer
Centre the backing washer over the connection cable. If
necessary, secure it to the wall with adhesive. Offer up the
towel warmer, position the connection box on the washer, and
mark the screw holes on the wall brackets. Install the towel
warmer.
Connection
Pass the cable or equivalent through bushing D, ensuring that
the sealing effect is maintained. Connect the incoming wire to
terminal B on the insert; see fig. 8 and 9. Place the insert in the
connection box and connect wires A to the heating element.
Make sure that bushing D is correctly positioned. Fit the cover,
so that the round part covers the hole previously used for the
connection cable.
When using a backing washer, the connection box must be
raised about 1 mm above the backing washer to allow the lid
to be fitted; see fig. 10. Slacken the screws a little on the
nearest wall bracket and pull the towel warmer from the wall.
Fit the cover and push the connection box into the backing
washer; see fig. 10 and 11. Screw the cover and the wall brack-
et securely in place.
OPERATION
Switch on the towel warmer by moving the switch/knob to
position I. The towel warmer can be in constant operation
without any risk.The temperature of the pipes may vary.
For the TFR and TTR models, the surface temperature is
adjustable between ca. 38ºC and 60ºC. Chose a temperature
by turning the knob clockwise for higher temperature.
CARE
Use only mild cleaning agents when cleaning and wiping of the
towel warmer is necessary.
CAUTION
If the instructions for fitting and use are not followed, this may
lead to overheating and malfunction.
If the connection cable to this towel warmer is damaged, it
must be replaced with a special type of cable supplied by the
manufacturer or his representative.The LVI article number for
the connection cable for the TF/TFR and TT/TTR models is
642 0601 (with plug) and 641 0601 (without plug).
The maximum surface temperature that can be reached by an
exposed surface is 60°C.
This towel warmer is filled with a precise quantity of liquid, and
any repairs that involve opening the towel warmer must be
carried out by the manufacturer or his service representative.
Any leakage must be dealt with by the manufacturer or his
representative.
The liquid in the towel warmer is not affected by temperatures
below 0°C.
The appliance is not intended for use by young or infirm per-
sons without supervision.Young children should be supervised
to ensure that they do not play with the appliance.
If the appliance is supplied from a cord extension set or
electrical portable outlet device, the cord extension set or
electrical portable outlet device should be positioned so it is
not subjected to splashing or ingress of water.
Towel warmers are backed by a 2-year warrenty
Please contact your supplier in the event of any problems or if
repairs are necessary.