Take a moment to get familiar with the cleaner using the figure 3. Throughout this manual reference to this
figure is made when referring to different components of the cleaner.
Remove the cleaner by placing the carton down and
removing it from the box as shown. On models which
include a caddy cart the cleaner and the Power Supply
are pre-mounted to the cart.
See the figure 4 for Caddy Cart.
1. Select the nearest GFCI (Ground Fault Circuit Interrupter) protected 110-120 volt AC outlet.
2. Place the cleaner power supply so that it is at a minimum distance of 11.5 feet (3.5 meters) from the
pool edge. The length of the standard cleaner cable is 60 feet (18.29 meters).
3. Stretch out the floating cable along the pool deck to remove any twisting the cord has from storage
and measure out the approximate amount of cleaner cord needed for pool coverage.
4. Connect the floating cable to the power supply. Use only the original Power Supply manufactured by
Hayward.
4. Place the cleaner in the pool. It will slowly sink to the bottom of the pool as the air inside is released.
5. Connect the power supply to the protected outlet and switch it on. The cleaner will perform a self-
diagnostics routine before starting the cleaning cycle for several minutes.
Notice: To reduce risk of injury and prevent damage to the cleaner the start up sequence the
cleaner has been equipped with an out of water sensor. Should the cleaner sense that it is not in
the water it will power itself down. To reset the cycle switch off the power supply for 10 seconds
and restart.
6. The cleaner will automatically shut off after 3 hours for a full cleaning cycle. If your pool is cleaned in
less time than 3 hours, you may shut the cleaner off manually by switching the power supply to the off
position. Should a second cleaning cycle be required, switch OFF the power supply for 10 seconds and
restart.
7. After the pool has been cleaned, switch OFF the power supply before removing the cleaner from the pool.
GENERAL OPERATING INSTRUCTIONS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS