P100
Issue 08/07/2003
M
anual reset models pressure range and tolerances
Nominal setpoint
psig
bar **
200 to 250
14 to 17,2
251 to 350
17,3 to 24,1
351 to 500
24,2 to 34.5
501 to 750
34,6 to 52
Cut-in pressure is 70% (± 30 PSIG) of the nominal setpoint
L
P >
M
O
SPST-NO
LP protection
+ fan-cycling
P100AA,AE
Wire leads for SPDT contacts are marked: White = Common (1) Blue = N.O. (2) Black = N.C. (3)
R
epair and replacement
Repair is not possible. In case of an
improperly functioning control, please check
with your nearest supplier.
© 2003 Johnson Controls, Inc
Order No. PD-P100-E
Standard tolerance
psi
bar**
± 15
± 1
± 15
± 1
± 20
± 1,4
± 20
± 1,4
C
ontact functions
L
P >
M
O
Fig. 1
SPST-NC
HP protection
P100CA,DA,CE
Minimum tolerance*
L
1
P >
3
2
M
O
SPDT
HP protection
P100EE
When contacting the supplier for a
replacement you should state the type/model
number of the control. This number can be
found on the data plate.
psi
bar **
± 7
± 0.5
± 7
± 0.5
± 7
± 0,5
10
0,7
L
1
P >
3
2
M
O
SPDT
LP protection
P100EE
Catalogue Section 6
3