The Remote Control must be fixed to the wall, at about 1.5 m above the floor, in a place away from entrance doors, windows or heat sources that can affect the room temperature.
Before installing, disconnect the power to the boiler. Remove the front part of the Remote Control by prising with a screwdriver at points A. Then fix the rear part of the Remote Control
to the wall with the set of fastening screws supplied, making sure to run the 2 wires inside the holes located above the terminals. Use the "COM" terminals for the electrical connection.
If the telephone contact (voltage-free contact) has to be connected, use the "AUX" terminals. Reinsert the front part of the Remote Control
A
C O M
A U X
A
Use a bipolar cable (2x0.75mm2, max 2x2.5mm2) making sure its path is not the same as that of the mains power cables. The maximum cable length must not exceed 50m.