14. Never connect the filter to the public water supply network.
15. Devices with obvious damage must not be operated.
16. Do not let the pump run dry (without water flow). To avoid an overheating of the
lamp, please switch of the lamp if there is no direct water flow.
17. Attention! Temporarily stop the operation of the UVC lamp, while treating the
water or fish inside your pond with additional care products.
Attention! Use in garden ponds and the protected area of garden ponds is only
permitted if the installation complies with the valid regulations. Consult a qualified
electrician.
DO NOT use the pump in or on swimming pools!
2. Scope of delivery
T.I.P. UV-C lamp, 2 clamping brackets, 2 hose connectors, operating instruction.
Check the device for transport damage and complete delivery. If there is damage the retailer must
be notified without delay, at the latest however, within 8 days of the purchase date.
3. Application areas
This UV-C lamp is intended for use in garden or fish ponds to clean polluted pond water. This
device has been developed for private use and not for industrial or commercial purposes.
4. Technical data
Model
Power consumption of the UV-C
UV-C-tube type / performance
Service life of the UVC tube
Degree of protection / protection class - UVC emitter
Length of the connecting cable - UVC emitter
Voltage / frequency, primary (input)
Degree of protection - transformer
Max. flow rate (Qmax)
Operating pressure max. (pmax)
Maximum temperature of the pumped liquid (Tmax)
Minimum temperature of the pumped liquid
For ponds up to
Weight (net)
Filter dimensions, mounted (W x D x H)
Article No.
10
UV-C-PJ 11W
13 W
G 23 / 11 W
ca. 4.000 h
IPX4
5 m
230 V~ / 50 Hz
IPX4
3,000 l/h
0,3 bar
35 °C
5 °C
10,000 l
1.2 kg
29 x 25,2 x 8 cm
30432
3