37 Limitation of liability

RIPEnergy AG is not responsible or liable for any loss, damage or costs arising from operating these inverters.
The products supplied by RIPEnergy AG are not for applications in any medical equipment intended for use as a
component of any life support system. If products are used in such systems, a specific written agreement
between the manufacturer, RIPEnergy AG and the installer/manufacturer of the system is needed. In addition, the
manufacturer of the system must agree to indemnify RIPEnergy AG from any claims arising from use of products
supplied by RIPEnergy AG in the life support equipment.

38 Warranty specifications (short form)

The inverters are built for RIPEnergy AG in according to the legally applicable standards. During production, and
prior to delivery, all products are tested and inspected. RIPEnergy AG is looking to find the best available
products on the market. Good quality parts and the latest technology of the units will ensure a long lasting and
trouble free operation of these units.
If any problem occurs during warranty period, please contact your dealer first. He is able to serve you with
instructions and explains you how to send the unit to the nearest service center, if necessary.
Warranty can only be guaranteed if you enclose a document (Invoice or delivery documents) to the defective
units.
Damage attributable to normal wear and tear, overload or improper handling or installation is not covered by the
warranty.
Modifications or breaking the warranty label without a written permission from RIPEnergy AG means that the
warranty is lost immediately!
Always return the units in it's original package and completely assembled. A short description of the
failure/problem will help us to serve you better.
RIPEnergy AG is not paying for costs arising for transport of the unit or damage that arise during the time the unit
is unserviceable. The general terms of delivery and terms of sale of RIPEnergy AG are valid.

39 Unpacking

After unpacking, carefully check the inverter for possible damage. If any damage due to transport is visible
immediately contact your dealer for further instructions.
Keep the original packing in case you need it to transport the inverter later.

40 Environmental protection

RIPEnergy AG continually commits a considerable part of its resources towards minimizing the environmental
impact of its products. The inverter is manufactured with valuable materials and easy to recycle.

41 Description of the inverter

The pure sinewave inverter supplies a 230VAC output voltage either from a 12V, 24V or 48VDC
power source. The shape of the output voltage is pure sinewave - clean power as from the grid.
The inverter design is based on state of the art high frequency technology. All functions are controlled
by a microprocessor. Extra input and output filtering to reduce EMI to extremely low levels. Reliability
features include an input fuse, thermal shutdown, current limiting and output short circuit shutdown
with automatic recovery.
The input and output is fully isolated. The superb overload capability supplies short time peak power to
start heavy equipment such as pumps and compressors.