INSTALATION
1. The input voltage is AC 12V. The lamp must be connected to a transformer.
110V / 220V
2. The PAR56 bulb must be used underwater. The test time in the air should be 2 minutes.
3. Check the silicone O-ring before installing the PAR56. If the o-ring is aged, you must replace the new one.
4. Make sure that the O-ring is in the correct position; otherwise, it will damage PAR56
Refs. 97900-97901
5. Lock the screws diagonally, without problems. Do not fast them thoroughly, otherwise it will damage the lamp and
the niche.
6. If the cable connection is made under water, the connection part must be waterproof (use a waterproof gland or fill it
with epoxy glue). Otherwise, the water will enter the lamp through the wires. Position A.
7. The junction box must be higher than the water level. Position B.
INSTRUÇÕES IMPORTANTES DE SEGURANÇA / IMPORTANT SAFETY INSTRUCTIONS
TRANSFORMER
Ref. 97902
B
A
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
AC 12V
1200mm
Water Level
-7-
(PAR56)