4.1
Intended use
Exclusively use the GA InScenio FM Master WLAN as follows:
• Operation only as a power supply distributor for suitable OASE products.
• Operation only at ambient temperatures of -20 °C ... +45 °C.
• Operate in accordance with instructions.
The following restrictions apply to the GA InScenio FM Master WLAN:
• Do not connect any units that could pose danger to persons or assets and that have to be immediately swit-
ched off in an emergency.
• Do not operate in or under water.
5
Installation and connection
W A R N I N G
Electrical current may cause death or severe injuries.
• Ensure that the unit is installed in a flood protected position at a distance of at least 2 m from the
water.
• Operate the unit with a protective hood fitted.
5.1
Connecting the antenna
How to proceed:
C
1. Remove the blind plug and screw the antenna into place.
2. Align the antenna.
5.2
Setting up the InScenio FM-Master WLAN
How to proceed:
B
• Install the unit at least 2 m from the edge of the pond.
• Do not expose the unit to direct sunlight.
D
1. Insert the ground stake by approx. ¾ of its length into the ground.
2. Slide the device onto the ground stake.
3. With the unit, push the ground stake fully into the ground.
4. Check its stability.
5.3
Connecting the power supply
How to proceed:
E
Unit version with power plug:
• Push the coupling of the power cable onto the unit plug.
F
Unit version with power cable:
• Connect the unit to the power supply.
– Work on the power supply may only be carried out by a qualified electrician.
– Adhere to the pin assignment specified on the power cable label.
– Only use wires with wire end ferrules for connection.
- EN -